Skip to main content
Install and maintain

Replace an I/O module - AFF C80

Contributors netapp-jsnyder netapp-lisa

Replace an I/O module in your AFF C80 system when the module fails or requires an upgrade to support higher performance or additional features. The replacement process involves shutting down the controller, replacing the failed I/O module, rebooting the controller, and returning the failed part to NetApp.

To replace an I/O module, locate it within the controller module and follow the specific sequence of steps.

Steps
  1. If you are not already grounded, properly ground yourself.

  2. Unplug any cabling on the target I/O module.

    Make sure to label the cables so that you know where they came from.

  3. Rotate the cable management tray down by pulling the buttons on the inside of the cable management tray and rotating it down.

  4. Remove the I/O module from the controller module:

    Note This following illustration shows removing a horizontal and vertical I/O module. Typically, you will only remove one I/O module.
    Remove I/O module

    Callout number 1

    Cam locking button

    1. Depress the cam latch button.

    2. Rotate the cam latch do away from the module as far as it will go.

    3. Remove the module from the controller module by hooking your finger into the cam lever opening and pulling the module out of the controller module.

      Make sure that you keep track of which slot the I/O module was in.

  5. Set the I/O module aside.

  6. Install the replacement I/O module into the target slot:

    1. Align the I/O module with the edges of the slot.

    2. Gently slide the module into the slot all the way into the controller module, and then rotate the cam latch all the way up to lock the module in place.

  7. Cable the I/O module.

  8. Repeat the remove and install steps to replace additional modules for the controller.

  9. Rotate the cable management tray into the locked position.