Boot the recovery image - FAS500f
You must boot the ONTAP image from the USB drive, restore the file system, and verify the environmental variables.
-
From the LOADER prompt, boot the recovery image from the USB flash drive:
boot_recoveryThe image is downloaded from the USB flash drive.
-
When prompted, either enter the name of the image or accept the default image displayed inside the brackets on your screen.
-
Restore the var file system:
If your system has… Then… A network connection
-
Press
ywhen prompted to restore the backup configuration. -
Set the healthy controller to advanced privilege level:
set -privilege advanced -
Run the restore backup command:
system node restore-backup -node local -target-address impaired_node_IP_address -
Return the controller to admin level:
set -privilege admin -
Press
ywhen prompted to use the restored configuration. -
Press
ywhen prompted to reboot the controller.
No network connection
-
Press
nwhen prompted to restore the backup configuration. -
Reboot the system when prompted by the system.
-
Select the Update flash from backup config (sync flash) option from the displayed menu.
If you are prompted to continue with the update, press
y.
No network connection and is in a MetroCluster IP configuration
-
Press
nwhen prompted to restore the backup configuration. -
Reboot the system when prompted by the system.
-
Wait for the iSCSI storage connections to connect.
You can proceed after you see the following messages:
date-and-time [node-name:iscsi.session.stateChanged:notice]: iSCSI session state is changed to Connected for the target iSCSI-target (type: dr_auxiliary, address: ip-address). date-and-time [node-name:iscsi.session.stateChanged:notice]: iSCSI session state is changed to Connected for the target iSCSI-target (type: dr_partner, address: ip-address). date-and-time [node-name:iscsi.session.stateChanged:notice]: iSCSI session state is changed to Connected for the target iSCSI-target (type: dr_auxiliary, address: ip-address). date-and-time [node-name:iscsi.session.stateChanged:notice]: iSCSI session state is changed to Connected for the target iSCSI-target (type: dr_partner, address: ip-address).
-
Select the Update flash from backup config (sync flash) option from the displayed menu.
If you are prompted to continue with the update, press
y.
-
-
Ensure that the environmental variables are set as expected:
-
Take the controller to the LOADER prompt.
-
Check the environment variable settings with the
printenvcommand. -
If an environment variable is not set as expected, modify it with the
setenv environment-variable-name changed-valuecommand. -
Save your changes using the
savenvcommand.
-
-
The next depends on your system configuration:
-
If your system has onboard keymanager, NSE or NVE configured, go to Restore OKM, NSE, and NVE as needed
-
If your system does not have onboard keymanager, NSE or NVE configured, complete the steps in this section.
-
-
From the LOADER prompt, enter the
boot_ontapcommand.If you see… Then… The login prompt
Go to the next Step.
Waiting for giveback…
-
Log into the partner controller.
-
Confirm the target controller is ready for giveback with the
storage failover showcommand.
-
-
Connect the console cable to the partner controller.
-
Give back the controller using the
storage failover giveback -fromnode localcommand. -
At the cluster prompt, check the logical interfaces with the
net int -is-home falsecommand.If any interfaces are listed as "false", revert those interfaces back to their home port using the
net int revertcommand. -
Move the console cable to the repaired controller and run the
version -vcommand to check the ONTAP versions. -
Restore automatic giveback if you disabled it by using the
storage failover modify -node local -auto-giveback truecommand.