View error codes (SGF6112)
If a hardware error occurs when the appliance is booting up, the BMC logs an error code. As required, you can view these error codes using the BMC interface, and then work with technical support to resolve the issue.
-
You know how to access the BMC dashboard.
-
From the BMC dashboard, select BIOS POST Code.
-
Review the information displayed for Current Code and the Previous Code.
If any of the following error codes are shown, work with technical support to resolve the issue.
Code Indicates 0x0E
Microcode not found
0x0F
Microcode not loaded
0x50
Memory initialization error. Invalid memory type or incompatible memory speed.
0x51
Memory initialization error. SPD reading has failed.
0x52
Memory initialization error. Invalid memory size or memory modules don't match.
0x53
Memory initialization error. No usable memory detected.
0x54
Unspecified memory initialization error
0x55
Memory not installed
0x56
Invalid CPU type or speed
0x57
CPU mismatch
0x58
CPU self-test failed, or possible CPU cache error
0x59
CPU micro-code is not found, or micro-code update failed
0x5A
Internal CPU error
0x5B
Reset PPI is not available
0x5C
PEI phase BMC self-test failure
0xD0
CPU initialization error
0xD1
North bridge initialization error
0xD2
South bridge initialization error
0xD3
Some architectural protocols aren't available
0xD4
PCI resource allocation error. Out of resources.
0xD5
No space for legacy option ROM
0xD6
No console output devices are found
0xD7
No console input devices are found
0xD8
Invalid password
0xD9
Error loading boot option (LoadImage returned error)
0xDA
Boot option failed (StartImage returned error)
0xDB
Flash update failed
0xDC
Reset protocol is not available
0xDD
DXE phase BMC self-test failure
0xE8
MRC: ERR_NO_MEMORY
0xE9
MRC: ERR_LT_LOCK
0xEA
MRC: ERR_DDR_INIT
0xEB
MRC: ERR_MEM_TEST
0xEC
MRC: ERR_VENDOR_SPECIFIC
0xED
MRC: ERR_DIMM_COMPAT
0xEE
MRC: ERR_MRC_COMPATIBILITY
0xEF
MRC: ERR_MRC_STRUCT
0xF0
MRC: ERR_SET_VDD
0xF1
MRC: ERR_IOT_MEM_BUFFER
0xF2
MRC: ERR_RC_INTERNAL
0xF3
MRC: ERR_INVALID_REG_ACCESS
0xF4
MRC: ERR_SET_MC_FREQ
0xF5
MRC: ERR_READ_MC_FREQ
0x70
MRC: ERR_DIMM_CHANNEL
0x74
MRC: ERR_BIST_CHECK
0xF6
MRC: ERR_SMBUS
0xF7
MRC: ERR_PCU
0xF8
MRC: ERR_NGN
0xF9
MRC: ERR_INTERLEAVE_FAILURE