Skip to main content
ONTAP MetroCluster
La versione in lingua italiana fornita proviene da una traduzione automatica. Per eventuali incoerenze, fare riferimento alla versione in lingua inglese.

Ridenominazione di uno switch FC Brocade

Collaboratori

Potrebbe essere necessario rinominare uno switch FC Brocade per garantire un nome coerente in tutta la configurazione.

Fasi
  1. Disabilitare in modo persistente lo switch o gli switch in un fabric:

    switchcfgpersistentdisable

    L'esempio seguente mostra l'output per switchcfgpersistentdisable comando:

    7840_FCIP_2:admin> switchcfgpersistentdisable
    Switch's persistent state set to 'disabled'
    2018/03/09-07:41:06, [ESM-2105], 146080, FID 128, INFO, 7840_FCIP_2, VE Tunnel 24 is DEGRADED.
    2018/03/09-07:41:06, [ESM-2104], 146081, FID 128, INFO, 7840_FCIP_2, VE Tunnel 24 is OFFLINE.
    
    7840_FCIP_2:admin>
  2. Rinominare lo switch o gli switch:

    switchname new-switch-name

    Se si stanno rinominando entrambi gli switch nel fabric, utilizzare lo stesso comando su ogni switch.

    L'esempio seguente mostra l'output per switchname new-switch-name comando:

    7840_FCIP_2:admin> switchname FC_switch_1_B
    Committing configuration...
    Done.
    Switch name has been changed.Please re-login into the switch for the change to be applied.
    2018/03/09-07:41:20, [IPAD-1002], 146082, FID 128, INFO, FC_switch_1_B, Switch name has been successfully changed to FC_switch_1_B.
    7840_FCIP_2:admin>
  3. Riavviare lo switch:

    reboot

    Se si stanno rinominando entrambi gli switch nel fabric, riavviare entrambi gli switch. Una volta completato il riavvio, lo switch viene rinominato in tutte le posizioni.

    L'esempio seguente mostra l'output per reboot comando:

    7840_FCIP_2:admin> reboot
    Warning: This command would cause the switch to reboot
    and result in traffic disruption.
    Are you sure you want to reboot the switch [y/n]?y
    2018/03/09-07:42:08, [RAS-1007], 146083, CHASSIS, INFO, Brocade7840, System is about to reload.
    Rebooting! Fri Mar  9 07:42:11 CET 2018
    
    Broadcast message from root (ttyS0) Fri Mar  9 07:42:11 2018...
    
    The system is going down for reboot NOW !!
    INIT: Switching to runlevel: 6
    INIT:
    2018/03/09-07:50:48, [ESM-1013], 146104, FID 128, INFO, FC_switch_1_B, DP0 Configuration replay has completed.
    2018/03/09-07:50:48, [ESM-1011], 146105, FID 128, INFO, FC_switch_1_B, DP0 is ONLINE.
    
    *** CORE FILES WARNING (03/09/18 - 08:00:00 ) ***
    10248 KBytes in 1 file(s)
    use "supportsave" command to upload
    
    
    *** FFDC FILES WARNING (03/09/18 - 08:00:00 ) ***
    520 KBytes in 1 file(s)
  4. Abilitare costantemente gli switch: switchcfgpersistentenable

    L'esempio seguente mostra l'output per switchcfgpersistentenable comando:

    FC_switch_1_B:admin> switchcfgpersistentenable
    Switch's persistent state set to 'enabled'
    FC_switch_1_B:admin>
    FC_switch_1_B:admin>
    FC_switch_1_B:admin> 2018/03/09-08:07:07, [ESM-2105], 146106, FID 128, INFO, FC_switch_1_B, VE Tunnel 24 is DEGRADED.
    2018/03/09-08:07:10, [ESM-2106], 146107, FID 128, INFO, FC_switch_1_B, VE Tunnel 24 is ONLINE.
    
    FC_switch_1_B:admin>
    
    
    FC_switch_1_B:admin> switchshow
    switchName:     FC_switch_1_B
    switchType:     148.0
    switchState:    Online
    switchMode:     Native
    switchRole:     Subordinate
    switchDomain:   6
    switchId:       fffc06
    switchWwn:      10:00:50:eb:1a:9a:a5:79
    zoning:         ON (CFG_FAB_2_RCF_9_3)
    switchBeacon:   OFF
    FC Router:      OFF
    FC Router BB Fabric ID: 128
    Address Mode:   0
    HIF Mode:       OFF
    
    Index Port Address  Media Speed   State       Proto
    ==================================================
       0   0   060000   id    16G     Online      FC  F-Port  50:0a:09:81:06:a5:5a:08
       1   1   060100   id    16G     Online      FC  F-Port  50:0a:09:83:06:a5:5a:08
  5. Verificare che la modifica del nome dello switch sia visibile dal prompt del cluster ONTAP:

    storage switch show

    L'esempio seguente mostra l'output per storage switch show comando:

    cluster_A::*> storage switch show
      (storage switch show)
                          Symbolic                                Is        Monitor
    Switch                Name     Vendor  Model Switch WWN       Monitored Status
    --------------------- -------- ------- ----- ---------------- --------- -------
    Brocade_172.20.7.90
                          RTP-FC01-510Q40
                                   Brocade Brocade7840
                                                 1000c4f57c904bc8 true      ok
    Brocade_172.20.7.91
                          RTP-FC02-510Q40
                                   Brocade Brocade7840
                                                 100050eb1a9aa579 true      ok
    Brocade_172.20.7.92