nvmeof.mixedports events
nvmeof.mixedports.clear
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when there is no longer a nonrecommended mix of a dedicated port and a nondedicated port cabled from a node to a shelf.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
There is no longer a nonrecommended mix of a dedicated port and a nondedicated port cabled from node %s to shelf with SN %s.
 - Parameters
 - 
node_name (STRING): Host port connected to the cable.
shelf_sn (STRING): Serial number of the shelf connected to the cable. 
nvmeof.mixedports.error
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when both primary and secondary host ports are incorrectly cabled to a shelf. This cabling might compromise physical data link redundancy and inhibit system performance.
 - Corrective Action
 - 
Connect either primary dedicated ports or secondary nondedicated ports to the shelf, but not both port types.
 - Syslog Message
 - 
There is a nonrecommended mix of a dedicated port and a nondedicated port cabled from node %s to Shelf with SN %s.
 - Parameters
 - 
node_name (STRING): Host port connected to the cable.
shelf_sn (STRING): Serial number of the shelf connected to the cable.