nvmeof.mixedports events
Collection of separate PDF docs
Creating your file...
nvmeof.mixedports.clear
- Severity
-
NOTICE
- Description
-
This message occurs when there is no longer a nonrecommended mix of a dedicated port and a nondedicated port cabled from a node to a shelf.
- Corrective Action
-
(None).
- Syslog Message
-
There is no longer a nonrecommended mix of a dedicated port and a nondedicated port cabled from node %s to shelf with SN %s.
- Parameters
-
node_name (STRING): Host port connected to the cable.
shelf_sn (STRING): Serial number of the shelf connected to the cable.
nvmeof.mixedports.error
- Severity
-
ERROR
- Description
-
This message occurs when both primary and secondary host ports are incorrectly cabled to a shelf. This cabling might compromise physical data link redundancy and inhibit system performance.
- Corrective Action
-
Connect either primary dedicated ports or secondary nondedicated ports to the shelf, but not both port types.
- Syslog Message
-
There is a nonrecommended mix of a dedicated port and a nondedicated port cabled from node %s to Shelf with SN %s.
- Parameters
-
node_name (STRING): Host port connected to the cable.
shelf_sn (STRING): Serial number of the shelf connected to the cable.