disk.maint events
Collection of separate PDF docs
Creating your file...
disk.maint.test.end
- Severity
-
NOTICE
- Description
-
This message occurs when maintenance testing has completed.
- Corrective Action
-
(None).
- Syslog Message
-
Disk %s Model [%s] S/N [%s] has completed maintenance testing with status %d (0x%x,0x%x,0x%x,0x%x).
- Parameters
-
disk_name (STRING): Name of the disk.
productID (STRING): Product name of the disk.
serialno (STRING): Serial number of the disk.
status (INT): Maintenance test completion status where 0 represents successful completion of the test.
fa0 (INTHEX): Failure byte 0.
fa1 (INTHEX): Failure byte 1.
fa2 (INTHEX): Failure byte 2.
fa3 (INTHEX): Failure byte 3.
disk.maint.test.start
- Severity
-
NOTICE
- Description
-
This message occurs when maintenance testing begins on a disk.
- Corrective Action
-
(None).
- Syslog Message
-
Disk %s Model [%s] S/N [%s] has started maintenance testing.
- Parameters
-
disk_name (STRING): Name of the disk.
productID (STRING): Product name of the disk.
serialno (STRING): Serial number of the disk.