Storage Firmware Bundle 2.182.0 Release Notes
Beginning with Element 12.0 and management services version 2.14, you can perform firmware-only upgrades on your storage nodes using the NetApp Hybrid Cloud Control UI and REST API. This procedure does not upgrade Element software and enables you to upgrade storage firmware outside of a major Element release.
What's New
The storage firmware bundle version 2.182.0 contains general bugfixes.
Updated firmware components
This firmware package contains the following firmware versions (highlighted in bold text) for hardware components:
H610S
Component | H610S |
---|---|
BIOS |
3B14 |
BMC |
4.01.07 |
NIC, Mellanox CX4 |
14.25.1020 |
NIC, Mellanox CX5 |
16.32.1010 |
NVIDIMM, Smart Gen1 |
3.1 |
NVIDIMM, Smart Gen2 |
3.5 |
BPM, Smart Gen1 |
2.16 |
BPM, Smart Gen2 |
2.17 |
NVIDIMM, Micron Gen1 |
26.2c |
NVIDIMM, Micron Gen2 |
25.3c |
PGEM, Micron |
1.40 |
PM963, SED |
CXV8202Q |
PM963, N-SED |
CXV8501Q |
PM983, SED |
EDA5602Q |
PM983, N-SED |
EDA5900Q |
PM9A3, SED |
GDC5A02Q |
CD5, SED |
0109 |
CD5, N-SED |
0109 |
CD5, FIPS |
0108 |
PE8010, SED |
11093A10 |
PE8010, N-SED |
110B3A10 |
H410S
Component | H410S |
---|---|
BIOS |
NAT3.6 |
BMC |
07.02.00 |
NIC / Mellanox |
14.25.1020 |
RMS200 |
ae3b8cc |
RMS300 |
7d8422bc |
PM863, SED |
GXT5404Q |
PM863, N-SED |
GXT5103Q |
PM883, SED |
HXT7A04Q |
Hawk-4, SED |
8ENP7101 |
Hawk-4, N-SED |
8ENP6101 |
SF38410, SF19210, SF9605, and SF4805
Component | SF38410, SF19210, SF9605, and SF4805 |
---|---|
Broadcom NIC |
7.10.18 |
RMS200 |
ae3b8cc |
RMS300 |
7d8422bc |
SAS Adapter |
16.00.01.00 |
PM863, SED |
GXT5404Q |
PM863, N-SED |
GXT5103Q |
PM883, SED |
HXT7A04Q |
Hawk-4, SED |
8ENP7101 |
Hawk-4, N-SED |
8ENP6101 |
The following table specifies the supported component firmware versions in this Storage Firmware Bundle release for the SF38410, SFG19210, SF9605, and SF4805 storage nodes. However, these component firmware cannot be updated by way of the Storage Firmware Bundle. |
Component | SF38410, SF19210, SF9605, and SF4805 |
---|---|
BIOS |
2.8.0 |
iDRAC |
2.75.75.75 |
There has been no payload updates since Storage Firmware bundle 2.146. |
Resolved and known issues
See the Bugs Online tool for details of issues that have been resolved and for any new issues.
Accessing the Bugs Online tool
-
Navigate to the Bugs Online tool and select Element Software from the drop-down list:
-
In the keyword search field, type “Storage Firmware Bundle” and select New Search:
-
A list of resolved or open bugs is displayed. You can further refine the results as shown: