Starting with Element 12.0 and management services version 2.14, you can perform firmware-only upgrades on your storage nodes using the NetApp Hybrid Cloud Control UI and REST API. This procedure does not upgrade Element software and enables you to upgrade storage firmware outside of a major Element release.

Important For H610S storage nodes running Element software version 12.0, you should apply D-patch SUST-909 before you upgrade to storage firmware bundle 2.27. Contact NetApp Support to obtain the D-patch before you upgrade.

What's New

The storage firmware bundle version 2.27 contains various bug fixes and new features, including security vulnerability fixes. You can upgrade the storage firmware using the instructions in Upgrade storage firmware.

Updated firmware components

This firmware package contains the following firmware versions for hardware components, with updated versions in bold:

Component Dell R630 H410S H610S

BIOS

N/A

NA2.1

3B03

BMC

N/A

6.84.00

3.84.07

NIC / Mellanox

-

14.21.1000

14.22.1002

RMS200

ae3b8cc

7d8422bc

-

RMS300

7d8422bc

7d8422bc

-

NVDIMM, Smart

-

-

3.1

BPM, Smart

-

-

2.16

NVDIMM, Micron Gen1

-

-

26.2c

NVDIMM, Micron Gen2

-

-

25.3c

PGEM, Micron

-

-

1.40

PM863, SED

GXT5404Q

GXT5404Q

-

PM863, NSED

GXT5103Q

GXT5103Q

-

PM883, SED

HXT7104Q

HXT7104Q

-

Hawk-4, SED

8ENP7101

8ENP7101

-

Hawk-4, NSED

8ENP6101

8ENP6101

-

PM963, SED

-

-

CXV8202Q

PM963, NSED

-

-

CXV8501Q

PM983, SED

-

-

EDA5302Q

PM983, NSED

-

-

EDA5600Q

CD5, SED

-

-

0108

CD5, NSED

-

-

0108

CD5, FIPS

-

-

0108

New BMC features

The following are the new BMC features and changes included in this release:

  • (H610S) Enabled INITRD support, for loading an initial ramdisk at boot time

  • (H610S) Updated SSL help message about X.509 certificates

  • (H610S) Disabled TLS 1.0 and 1.1 support to resolve security vulnerabilities

  • (H610S, H410S) Added the ability to mount remote media using Redfish APIs

  • (H610S) Added support for HTML5 web browser BMC management

  • (H610S) Added remote syslog support, to help with remote data center monitoring and management

Resolved issues

The following are issues that have been resolved in this release:

Issue Description

N/A

The debug user sysadmin can log in using SSH after resetting the BMC.

N/A

When you use the console to ping the BMC IP address, the BMC does not respond.

N/A

During an AC power cycle stress test, the access permissions of the SOLSSH config file are lost.

CSESF-116

During an AC power cycle stress test, "PROCHOT" CPU thermal warnings appear in the BMC logs.

CSESF-121

The create and update service account API takes longer than expected.

CSD-3321 / CSESF-129

The H610S BMC can hang and become inaccessible with the error "BMC Self Test Failed".

CSESF-197

The BMC web UI inventory API returns the wrong memory serial number format.

Resolved security vulnerabilities

The following are security vulnerabilities that have been resolved in this release:

H410S BMC 6.84.00

  • CVE-2019-16649

  • CVE-2019-16650

  • CVE-2019-6260

H610S BMC 3.84.07

  • CVE-2019-1552

  • CVE-2019-1547, CVE-2019-1563

  • CVE-2019-5482

  • CVE-2019-15903

  • CVE-2018-20843

  • CVE-2019-14821, CVE-2019-15916, CVE-2019-16413

  • CVE-2019-10638, CVE-2019-10639

  • CVE-2019-11478, CVE-2019-11479, CVE-2019-11477

  • CVE-2019-12819

  • CVE-2019-14835, CVE-2019-14814, CVE-2019-14816, CVE-2019-16746

  • CVE-2019-19062

  • CVE-2019-19922, CVE-2019-20054

  • CVE-2019-19447, CVE-2019-19767, CVE-2019-10220

Known issues