event config force-sync
Synchronize a node's EMS configuration with the cluster wide EMS configuration
Availability: This command is available to cluster administrators at the advanced privilege level.
Description
The event config force-sync
command forces a node's EMS configuration to be synchronized with the cluster wide EMS configuration. The configuration is automatically synchronized among all nodes in the cluster, but in rare cases a node may not be updated. This command simplifies the recovery from this issue.
The following example shows where this command is useful: An email destination is configured for all CRITICAL level event occurrences. When the event is generated, all nodes generate an email except one. This command forces that node to refresh a stale configuration.
Parameters
[-node {<nodename>|local}]
- Node (privilege: advanced)-
The node parameter specifies which controller will be synchronized.