Skip to main content

event config force-sync

Contributors
Suggest changes

Synchronize a node's EMS configuration with the cluster wide EMS configuration

Availability: This command is available to cluster administrators at the advanced privilege level.

Description

The event config force-sync command forces a node's EMS configuration to be synchronized with the cluster wide EMS configuration. The configuration is automatically synchronized among all nodes in the cluster, but in rare cases a node may not be updated. This command simplifies the recovery from this issue.

The following example shows where this command is useful: An email destination is configured for all CRITICAL level event occurrences. When the event is generated, all nodes generate an email except one. This command forces that node to refresh a stale configuration.

Parameters

[-node {<nodename>|local}] - Node (privilege: advanced)

The node parameter specifies which controller will be synchronized.