system ha interconnect config show
Display the high-availability interconnect configuration information
Availability: This command is available to cluster administrators at the advanced privilege level.
Description
The system ha interconnect config show
command displays the high-availability interconnect device basic configuration information.
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>,…
parameter, the command displays only the fields that you specify. - |
[-instance ]
} -
Use this parameter to display all the fields from all nodes in cluster.
[-node {<nodename>|local}]
- Node (privilege: advanced)-
Use this parameter to display all the fields from the specified node in the cluster.
[-transport <text>]
- Interconnect Type (privilege: advanced)-
Selects the nodes that match this HA interconnect transport type.
[-local-sysid <integer>]
- Local System ID (privilege: advanced)-
Selects the nodes that match this local system unique identifier.
[-partner-sysid <integer>]
- Partner System ID (privilege: advanced)-
Selects the nodes that match this partner system unique identifier.
[-initiator {local|partner}]
- Connection Initiator (privilege: advanced)-
Selects the nodes that match this parameter value. The value is the initiator of the connection request.
[-port-name <text>,…]
- Port (privilege: advanced)-
Selects the nodes that match this port name.
[-ipaddress <text>,…]
- IP Address (privilege: advanced)-
Selects the nodes that match this IP address.
[-interface {backplane|external}]
- Interface (privilege: advanced)-
Selects the nodes that match this parameter value.
external
means the HA interconnect links between partner nodes are connected externally.backplane
means the HA interconnect links between partner nodes are connected over the backplane.
Examples
The following example displays the HA interconnect configuration information on FAS8000 series nodes in the cluster:
cluster1::*> system ha interconnect config show Node: ic-f8040-01 Interconnect Type: Infiniband (Mellanox ConnectX) Local System ID: 536875713 Partner System ID: 536875678 Connection Initiator: local Interface: backplane Port IP Address Flags ---- ----------------- ----------- ib0a 192.0.3.236 0x0 ib0b 192.0.3.237 0x0 Node: ic-f8040-02 Interconnect Type: Infiniband (Mellanox ConnectX) Local System ID: 536875678 Partner System ID: 536875713 Connection Initiator: partner Interface: backplane Port IP Address Flags ---- ----------------- ----------- ib0a 192.0.3.96 0x0 ib0b 192.0.3.97 0x0 2 entries were displayed.
The following example displays the HA interconnect configuration information on FAS2500 series nodes in the cluster:
cluster1::*> system ha interconnect config show Node: ic-f2554-03 Interconnect Type: Infiniband (Mellanox Sinai) Local System ID: 1781036608 Partner System ID: 1780360209 Connection Initiator: local Interface: backplane Port IP Address Flags ---- ----------------- ----------- ib0a ib0a - Node: ic-f2554-04 Interconnect Type: Infiniband (Mellanox Sinai) Local System ID: 1780360209 Partner System ID: 1781036608 Connection Initiator: partner Interface: backplane Port IP Address Flags ---- ----------------- ----------- ib0a ib0a - 2 entries were displayed.