system node hardware unified-connect show
Displays information about Fibre Channel and converged networking adapters
Availability: This command is available to cluster administrators at the admin privilege level.
Description
This command manages Fibre Channel and converged networking adapters used by the storage subsystem. Use the command to show the current mode and FC-4 type of adapters or the capabilities of adapters.
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>, …
parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-capability ]
-
If this parameter is specified, the command displays the capabilities of the adapters.
- |
[-instance ]
} -
If you specify the
-instance
parameter, the command displays detailed information about all fields. [-node {<nodename>|local}]
- Node-
If this parameter is specified, the command displays information about Fibre Channel and converged networking adapters on the specified node.
[-adapter <text>]
- Adapter-
If this parameter is specified, the command displays information about the specified adapter.
[-current-mode {fc|cna}]
- Current Mode-
If this parameter is specified, the command displays adapters configured to the specified mode.
[-current-type {initiator|target|fcvi}]
- Current Type-
If this parameter is specified, the command displays adapters configured to the specified FC-4 type.
[-pending-mode {fc|cna}]
- Pending Mode-
If this parameter is specified, the command displays adapters configured to the specified mode on the next reboot.
[-pending-type {initiator|target|fcvi}]
- Pending Type-
If this parameter is specified, the command displays adapters configured to the specified FC-4 on the next reboot.
[-status-admin <text>]
- Administrative Status-
If this parameter is specified, the command displays adapters with the specified status.
[-supported-modes {fc|cna}]
- Supported Modes-
The list of modes that the adapter supports.
[-supported-fc-types {initiator|target|fcvi}]
- Supported FC Types-
The list of FC-4 types the adapter supports when configured into fc mode.
[-supported-cna-types {initiator|target|fcvi}]
- Supported CNA Types-
The list of FC-4 types the adapter supports when configured into cna mode.
Examples
The following example displays information about all Fibre Channel and converged networking adapters in the cluster:
cluster1::> system node hardware unified-connect show Current Current Pending Pending Admin Node Adapter Mode Type Mode Type Status ------------ ------- ------- --------- ------- --------- ----------- node1 0c fc initiator - - online node1 0d fc initiator - - online node1 3a fc target - - online node1 3b fc target - - online node1 4a cna target - - online node1 4b cna target - - online node1 6a fc target - - online node1 6b fc target - - online node2 0c fc initiator - - online node2 0d fc initiator - - online node2 3a fc target - - online node2 3b fc target - - online node2 4a cna target - - online node2 4b cna target - - online node2 6a cna target - - online node2 6b cna target - - online 16 entries were displayed.