Skip to main content

system node hardware unified-connect show

Contributors
Suggest changes

Displays information about Fibre Channel and converged networking adapters

Availability: This command is available to cluster administrators at the admin privilege level.

Description

This command manages Fibre Channel and converged networking adapters used by the storage subsystem. Use the command to show the current mode and FC-4 type of adapters or the capabilities of adapters.

Parameters

{ [-fields <fieldname>,…​]

If you specify the -fields <fieldname>, …​ parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.

| [-capability ]

If this parameter is specified, the command displays the capabilities of the adapters.

| [-instance ] }

If you specify the -instance parameter, the command displays detailed information about all fields.

[-node {<nodename>|local}] - Node

If this parameter is specified, the command displays information about Fibre Channel and converged networking adapters on the specified node.

[-adapter <text>] - Adapter

If this parameter is specified, the command displays information about the specified adapter.

[-current-mode {fc|cna}] - Current Mode

If this parameter is specified, the command displays adapters configured to the specified mode.

[-current-type {initiator|target|fcvi}] - Current Type

If this parameter is specified, the command displays adapters configured to the specified FC-4 type.

[-pending-mode {fc|cna}] - Pending Mode

If this parameter is specified, the command displays adapters configured to the specified mode on the next reboot.

[-pending-type {initiator|target|fcvi}] - Pending Type

If this parameter is specified, the command displays adapters configured to the specified FC-4 on the next reboot.

[-status-admin <text>] - Administrative Status

If this parameter is specified, the command displays adapters with the specified status.

[-supported-modes {fc|cna}] - Supported Modes

The list of modes that the adapter supports.

[-supported-fc-types {initiator|target|fcvi}] - Supported FC Types

The list of FC-4 types the adapter supports when configured into fc mode.

[-supported-cna-types {initiator|target|fcvi}] - Supported CNA Types

The list of FC-4 types the adapter supports when configured into cna mode.

Examples

The following example displays information about all Fibre Channel and converged networking adapters in the cluster:

cluster1::> system node hardware unified-connect show
                       Current  Current    Pending  Pending    Admin
Node          Adapter  Mode     Type       Mode     Type       Status
------------  -------  -------  ---------  -------  ---------  -----------
node1         0c       fc       initiator  -        -          online
node1         0d       fc       initiator  -        -          online
node1         3a       fc       target     -        -          online
node1         3b       fc       target     -        -          online
node1         4a       cna      target     -        -          online
node1         4b       cna      target     -        -          online
node1         6a       fc       target     -        -          online
node1         6b       fc       target     -        -          online
node2         0c       fc       initiator  -        -          online
node2         0d       fc       initiator  -        -          online
node2         3a       fc       target     -        -          online
node2         3b       fc       target     -        -          online
node2         4a       cna      target     -        -          online
node2         4b       cna      target     -        -          online
node2         6a       cna      target     -        -          online
node2         6b       cna      target     -        -          online
16 entries were displayed.