system switch ethernet modify
Modify information about an Ethernet switch's configuration
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The system switch ethernet modify
command is used to modify the settings of an Ethernet switch for health monitoring purposes. This command allows you to adjust various parameters related to the switch, including its device name, IP address, SNMP version, SNMPv2c community or SNMPv3 username, model, type, and monitoring status.
Parameters
-device <text>
- Device Name-
Name of the Ethernet switch that you want to modify. ONTAP utilizes this device name to recognize the SNMP agent it needs to interact with.
[-address <IP Address>]
- IP Address-
IP address of the switch's management interface. This address is used as the destination of SNMP traffic and SSH connections for the purpose of monitoring and log collection, respectively.
[-snmp-version {SNMPv1|SNMPv2c|SNMPv3}]
- SNMP Version-
SNMP version that ONTAP employs for sending SNMP requests for monitoring purposes. By default, SNMPv2c is used, as established by the Reference Configuration File (RCF) applied to the switch.
[-community-or-username <text>]
- SNMPv2c Community String or SNMPv3 Username-
Community string used for SNMPv2 authentication, or the SNMPv3 username for SNMPv3 security. By default, the community string for SNMPv2 authentication is set to
cshm1!
, as determined by the RCF that is applied to the switch. If SNMPv3 is used, the switch must be configured with the SNMPv3 username. [-type {cluster-network|management-network|storage-network}]
- Switch Network-
Switch type:
cluster-network
,storage-network
, ormanagement-network
. [-is-monitoring-enabled-admin {true|false}]
- Enable Switch Monitoring-
Monitoring status selected by the administrator, which is set to
true
by default when not specified. During maintenance periods, a switch not manually added might be repeatedly discovered and dropped, which could potentially generate unnecessary alerts if monitoring is enabled by default. In such cases, setting this parameter tofalse
disables the monitoring process.
Examples
Example 1: Modifies the IP address for the switch named SwitchA. All other settings of the switch are preserved.
cluster1::> system switch ethernet modify -device SwitchA -address 2.3.4.5
Example 2: Modifies the SNMP parameters for the switch named SwitchB. All other settings are preserved.
cluster1::> system switch ethernet modify -device SwitchB -snmp-version SNMPv3 -community-or-username snmpv3u1