storage disk fail
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
Fail the file system disk
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage disk fail
command can be used to manually force a file system disk to fail. It is used to remove a file system disk that may be logging excessive errors and requires replacement. To unfail a disk, use the storage disk unfail command.
Parameters
-disk <disk path name>
- Disk Name-
This parameter specifies the disk to be failed.
[-i, -immediate <true>]
- Fail immediately-
This parameter optionally specifies whether the disk is to be failed immediately. It is used to avoid Rapid RAID Recovery and remove the disk from the RAID configuration immediately. Note that when a file system disk has been removed in this manner, the RAID group to which the disk belongs enters degraded mode (meaning a disk is missing from the RAID group). If a suitable spare disk is available, the contents of the disk being removed are reconstructed onto that spare disk.
Examples
The following example fails a disk named 1.1.16 immediately:
cluster1::> storage disk fail -disk 1.1.16 -i true WARNING: The system will not prefail the disk and its contents will not be copied to a replacement disk before being failed out. Do you want to fail out the disk immediately? {y|n}: y