system service-processor image show
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
Display the details of currently installed Service Processor firmware image
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The system service-processor image show
command displays information about the currently installed firmware images on the Service Processor of each node in a cluster. You can limit output to specific types of information and specific nodes in the cluster, or filter output by specific field values.
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>, …
parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-instance ]
} -
If you specify the
-instance
parameter, the command displays detailed information about all fields. [-node {<nodename>|local}]
- Node-
Selects firmware image information for the Service Processor of the specified node.
[-image {primary|backup}]
- Image-
Selects firmware image information for the Service Processors that are running the primary or backup image as specified.
[-type {SP|NONE|BMC}]
- Type-
Selects firmware image information for the Service Processors of the specified type.
[-status {installed|corrupt|updating|auto-updating|none}]
- Image Status-
Selects firmware image information for the Service Processors whose image status matches the specified value.
[-is-current {true|false}]
- Is Image Current-
Selects firmware image information for the SP whose current image matches the specified status. This parameter indicates the partition (primary or backup) that the SP is currently booted from, not whether the installed firmware version is most current.
[-version <text>]
- Firmware Version-
Selects firmware image information for the Service Processors running the specified firmware version.
[-autoupdate {true|false}]
- Firmware Autoupdate-
Selects firmware image information for the Service Processors whose automatic update matches the specified configuration.
[-last-update-status {failed|passed}]
- Last Update Status-
Selects firmware image information for the Service Processors whose last update is of the specified status.
Examples
The following command displays basic firmware information for the Service Processors of all the nodes.
cluster1::> system service-processor image show Is Node Type Image Status Current Version ---------------- ----- ------- ----------- ------- -------- node1 SP primary installed true 2.2X8 backup installed false 2.2X5 node2 SP primary installed true 2.2X8 backup installed false 2.2X5 4 entries were displayed. cluster1::>
The following command displays all available firmware information for the Service Processors of all the nodes.
cluster1::> system service-processor image show -instance Node: node1 Image: primary Type: SP Image Status: installed Is Image Current: true Firmware Version: 2.2X8 Firmware Autoupdate: true Last Update Status: passed Node: node1 Image: backup Type: SP Image Status: installed Is Image Current: false Firmware Version: 2.2X5 Firmware Autoupdate: true Last Update Status: passed Node: node2 Image: primary Type: SP Image Status: installed Is Image Current: true Firmware Version: 2.2X8 Firmware Autoupdate: true Last Update Status: passed Node: node2 Image: backup Type: SP Image Status: installed Is Image Current: false Firmware Version: 2.2X5 Firmware Autoupdate: true Last Update Status: passed 4 entries were displayed. cluster1::>