vserver nvme subsystem map add

Contributors
Suggest changes

Add a namespace map

Availability: This command is available to cluster and Vserver administrators at the admin privilege level.

Description

The vserver nvme subsystem map add command creates an association on an NVMe namespace to an NVMe subsystem.

When you add an NVMe subsystem map, the following pre-conditions must hold:

  • The NVMe namespace must not be already mapped to a different subsystem.

  • There must be an FC-NVMe LIF on the NVMe namespace owning node.

Parameters

-vserver <Vserver Name> - Vserver Name

Specifies the Vserver.

-subsystem <text> - Subsystem

Specifies the NVMe target subsystem.

-path <path> - Namespace Path

Specifies the path of the NVMe namespace. Examples of correct NVMe namespace paths are /vol/vol1/ns1 and /vol/vol1/qtree1/ns1 .

Examples

cluster::*> vserver nvme subsystem map add -vserver vs_1 -subsystem sub_1 -path /vol/nsvol/namespace1

Adds an association on the NVMe namespace at the specified path to NVMe subsystem sub_1 on Vserver vs_1 .