mcc.auso events
mcc.auso.trigFailed
- Severity
 - 
EMERGENCY
 - Description
 - 
This message occurs when a trigger for automatic unplanned switchover fails to issue the operation.
 - Corrective Action
 - 
Verify the health of each node and that automatic unplanned switchover is enabled on both by using the "metrocluster node show" command. Use the "metrocluster switchover -forced-on-disaster true" command to switch over the DR-site storage manually.
 - Syslog Message
 - 
A trigger for Automatic Unplanned Switchover failed to issue the operation. Reason: %s.
 - Parameters
 - 
probableCauseDescription (STRING): Further description of the probable cause.
alertId (STRING): Identifier for this condition.
alertingResource (STRING): Unique name of the resource responsible for this condition.
alertingResourceName (STRING): Name of the resource responsible for this condition.
possibleEffect (STRING): Possible effect of the failure.
probableCause (STRING): Probable cause of the failure.
additionalInfo (STRING): Additional information about this failure. 
mcc.auso.triggered
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when the node triggers an automatic unplanned switchover on detection of a failure of the DR partner node.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
The node has triggered an Automatic Unplanned Switchover of the DR partner. Reason: %s. If Automatic Unplanned Switchover was triggered because of heartbeat loss, any ongoing dump on the partner may be aborted.
 - Parameters
 - 
cause (STRING): Cause for triggering automatic unplanned switchover.