monitor.chassispowersupply events
monitor.chassisPowerSupply.degraded
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when a power supply is degraded.
 - Corrective Action
 - 
A replacement power supply might be required. Contact NetApp technical support for further direction.
 - Syslog Message
 - 
Chassis power supply %d is degraded: %s
 - Parameters
 - 
ps_number (INT): Power supply number.
reasonText (STRING): Description of the degradation. 
monitor.chassisPowerSupply.notPresent
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when an expected a power supply is not present.
 - Corrective Action
 - 
Add a power supply to the controller chassis.
 - Syslog Message
 - 
Chassis power supply %d is not present.
 - Parameters
 - 
ps_number (INT): Power supply number.
 
monitor.chassisPowerSupply.off
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when a power supply is off.
 - Corrective Action
 - 
Turn on the power supply.
 - Syslog Message
 - 
Chassis power supply %d off.
 - Parameters
 - 
ps_number (INT): Power supply number.
 
monitor.chassisPowerSupply.ok
- Severity
 - 
INFORMATIONAL
 - Description
 - 
This message occurs when the power supply is OK.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Chassis power supply %d is OK.
 - Parameters
 - 
ps_number (INT): Power supply number.