monitor.shutdown events
Collection of separate PDF docs
Creating your file...
monitor.shutdown.brokenDisk
- Severity
-
EMERGENCY
- Description
-
This message occurs when an automatic shutdown sequence has been initiated due to a degraded RAID group that cannot be reconstructed because there are not enough appropriate spare disks. The timeout period is specified by the "raid.timeout" option, which defaults to 24 hours.
- Corrective Action
-
To recover from the shutdown, boot the system. Ensure that there are sufficient spare disks of the appropriate type so that the degraded RAID group can be reconstructed.
- Syslog Message
-
%s in RAID group "%s" %s broken. Halting system now.
- Parameters
-
type (STRING): Type of disk.
rgname (STRING): RAID group name.
verb (STRING): Description of the broken state.
monitor.shutdown.brokenDisk.pending
- Severity
-
NOTICE
- Description
-
This message occurs when an automatic shutdown sequence has been postponed due to RAID reconstruction.
- Corrective Action
-
(None).
- Syslog Message
-
%s in RAID group "%s" %s broken. Halting system in %d hour%s.
- Parameters
-
type (STRING): Type of disk.
rgname (STRING): RAID group name.
verb (STRING): Description of the broken state.
countdown (INT): Number of hours remaining to shutdown.
plural (STRING): Plural character.
monitor.shutdown.cancel
- Severity
-
NOTICE
- Description
-
This message occurs when an automatic shutdown sequence is canceled.
- Corrective Action
-
(None).
- Syslog Message
-
Automatic shutdown sequence canceled.
- Parameters
-
(None).
monitor.shutdown.cancel.brokenDisk
- Severity
-
NOTICE
- Description
-
This message occurs when an automatic shutdown sequence has been postponed due to RAID reconstruction
- Corrective Action
-
(None).
- Syslog Message
-
%s in RAID group "%s" %s broken. Halt delayed until %s finishes.
- Parameters
-
type (STRING): Type of disk.
rgname (STRING): RAID group name.
verb (STRING): Description of the broken state.
reason (STRING): Reason that the shutdown was postponed. Possible reasons are "RAID reconstruction" and "parity recomputation".
monitor.shutdown.cancel.nvramLowBatteries
- Severity
-
NOTICE
- Description
-
This message occurs when an automatic shutdown sequence has been postponed due to RAID reconstruction.
- Corrective Action
-
(None).
- Syslog Message
-
NVRAM batteries are dangerously low. Halt delayed until %s finishes.
- Parameters
-
reason (STRING): Reason that the shutdown was postponed. Possible reasons are "RAID reconstruct" and "parity recomputation".
monitor.shutdown.cancel.nvramLowBattery
- Severity
-
NOTICE
- Description
-
This message occurs when an automatic shutdown sequence has been postponed due to RAID reconstruction
- Corrective Action
-
(None).
- Syslog Message
-
NVRAM battery is dangerously low. Halt delayed until %s finishes.
- Parameters
-
reason (STRING): Reason that the shutdown was postponed. Possible reasons are "RAID reconstruct" and "parity recomputation".
monitor.shutdown.chassisOverTemp
- Severity
-
EMERGENCY
- Description
-
This message occurs when the chassis temperature is too hot. This is sent just before shutdown.
- Corrective Action
-
Ensure that sufficient cooling air is being supplied to the chassis and that the air inlets and outlets of the unit are not blocked.
- Syslog Message
-
Chassis temperature is too hot: %s
- Parameters
-
describe_toohot (STRING): Description of the condition.
monitor.shutdown.chassisUnderTemp
- Severity
-
ERROR
- Description
-
This message occurs when the system is shutting down because chassis temperature is too cold.
- Corrective Action
-
The appliance is in an environment that is too cold. Find a way to warm the environment around the appliance.
- Syslog Message
-
Chassis temperature is too cold: %s
- Parameters
-
describe_toocold (STRING): Description of the condition.
monitor.shutdown.emergency
- Severity
-
EMERGENCY
- Description
-
This message occurs when ONTAP® initiates an emergency shutdown.
- Corrective Action
-
Correct the condition noted in the reason field.
- Syslog Message
-
Emergency shutdown: %s
- Parameters
-
reason (STRING): Reason for the shutdown.
monitor.shutdown.ioexpansionOverTemp
- Severity
-
EMERGENCY
- Description
-
This message occurs when the I/O expansion module is too hot. This message is sent just before shutdown.
- Corrective Action
-
The system environment is too hot; cool the environment.
- Syslog Message
-
I/O expansion module is too hot: %s
- Parameters
-
describe_toohot (STRING): Reading and state of the temperature sensors on the I/O expansion module.
monitor.shutdown.ioexpansionUnderTemp
- Severity
-
EMERGENCY
- Description
-
This message occurs when the I/O expansion module is too cold. This message is sent just before shutdown.
- Corrective Action
-
The system environment is too cold; warm the environment.
- Syslog Message
-
I/O expansion module is too cold: %s
- Parameters
-
describe_toocold (STRING): Reading and state of the temperature sensors on the I/O expansion module.
monitor.shutdown.nvramLowBatteries
- Severity
-
EMERGENCY
- Description
-
This message occurs when the NVRAM power in a controller with multiple NVRAM batteries is dangerously low, and ONTAP® initiates a shutdown to protect user data.
- Corrective Action
-
Replace the controller NVRAM batteries.
- Syslog Message
-
Emergency shutdown: NVRAM batteries dangerously low in degraded mode. Replace the batteries immediately!
- Parameters
-
(None).
monitor.shutdown.nvramLowBatteries.pending
- Severity
-
ALERT
- Description
-
This message occurs when an automatic shutdown sequence is pending because of low NVRAM batteries voltage.
- Corrective Action
-
Replace the controller NVRAM batteries.
- Syslog Message
-
NVRAM batteries are dangerously low. Halting system in %d hour%s. Replace the batteries immediately!
- Parameters
-
countdown (INT): Hours remaining until shutdown.
plural (STRING): Grammatical number.
monitor.shutdown.nvramLowBattery
- Severity
-
EMERGENCY
- Description
-
This message occurs when the controller NVRAM voltage is dangerously low, and ONTAP® initiates a shutdown to protect user data.
- Corrective Action
-
Replace the controller NVRAM battery.
- Syslog Message
-
Emergency shutdown: NVRAM battery dangerously low in degraded mode. Replace the battery immediately!
- Parameters
-
(None).
monitor.shutdown.nvramLowBattery.pending
- Severity
-
ALERT
- Description
-
This message occurs when an automatic shutdown sequence is pending because of low NVRAM battery voltage.
- Corrective Action
-
Replace the controller NVRAM battery.
- Syslog Message
-
NVRAM battery is dangerously low. Halting system in %d hour%s. Replace the battery immediately!
- Parameters
-
countdown (INT): Hours remaining until shutdown.
plural (STRING): Grammatical number.