acp.exp events
Collection of separate PDF docs
Creating your file...
acp.exp.power.cycle
- Severity
-
INFORMATIONAL
- Description
-
This message occurs when the Alternate Control Path (ACP) Processor receives a command to power-cycle the SAS expander.
- Corrective Action
-
(None).
- Syslog Message
-
SAS expander power-cycle request sent to %s (%s), (disk shelf serial number: %s).
- Parameters
-
inband_id (STRING): In-band ID of the module.
ip (STRING): IP address of the module.
status (STRING): Status code returned by the 'expander power cycle' command.
acp.exp.power.cycle.failed
- Severity
-
INFORMATIONAL
- Description
-
This message occurs when the Alternate Controller Path Administrator fails in its attempt to power-cycle the SAS expander.
- Corrective Action
-
(None).
- Syslog Message
-
SAS expander power-cycle request sent to %s (%s) failed with status (%s), (disk shelf serial number: %s).
- Parameters
-
inband_id (STRING): In-band ID of the module.
ip (STRING): IP address of the module.
status (STRING): Reason for the 'expander power-cycle' failure.
shelf_sno (STRING): Shelf serial number of the shelf where this I/O module is seated.
acp.exp.power.cycle.success
- Severity
-
INFORMATIONAL
- Description
-
This message occurs when an 'expander power cycle' command sent to the Alternate Controller Path (ACP) Processor succeeds.
- Corrective Action
-
(None).
- Syslog Message
-
SAS expander power cycle command sent to %s (%s) was successful, (disk shelf serial number: %s).
- Parameters
-
inband_id (STRING): In-band ID of the module.
ip (STRING): IP address of the module.
shelf_sno (STRING): Disk shelf serial number of the shelf where this I/O module is seated.
acp.exp.reset
- Severity
-
INFORMATIONAL
- Description
-
This message occurs when the Alternate Control Path (ACP) Processor receives a command to reset a SAS expander.
- Corrective Action
-
(None).
- Syslog Message
-
SAS expander reset issued to %s (%s), (disk shelf serial number: %s).
- Parameters
-
inband_id (STRING): In-band ID of the module.
ip (STRING): IP address of the module.
status (STRING): Status code returned by the 'expander reset' command.
acp.exp.reset.failed
- Severity
-
INFORMATIONAL
- Description
-
This message occurs when the Alternate Controller Path Administrator fails in its attempt to reset the SAS expander.
- Corrective Action
-
(None).
- Syslog Message
-
SAS expander reset request sent to %s (%s) failed with status (%s), (disk shelf serial number: %s).
- Parameters
-
inband_id (STRING): In-band ID of the module.
ip (STRING): IP address of the module.
status (STRING): Reason for the 'expander reset' failure.
shelf_sno (STRING): Disk shelf serial number of the shelf where this I/O module is seated.
acp.exp.reset.success
- Severity
-
INFORMATIONAL
- Description
-
This message occurs when an 'expander reset' command sent to the Alternate Controller Path (ACP) Processor succeeds.
- Corrective Action
-
(None).
- Syslog Message
-
SAS expander reset command sent to %s (%s) was successful, (disk shelf serial number: %s).
- Parameters
-
inband_id (STRING): In-band ID of the module.
ip (STRING): IP address of the module.
shelf_sno (STRING): Disk shelf serial number of the shelf where this I/O module is seated.
acp.exp.vpd.failed
- Severity
-
INFORMATIONAL
- Description
-
This message occurs when an attempt to get SAS expander VPD (Vital Product Data) data from the Alternate Control Path Processor fails.
- Corrective Action
-
(None).
- Syslog Message
-
An 'expander vpd' request sent to %s (%s) failed with status (%s), (disk shelf serial number: %s).
- Parameters
-
inband_id (STRING): In-band ID of the module.
ip (STRING): IP address of the module.
status (STRING): Reason for the failure to get the SAS expander vpd data.
shelf_sno (STRING): Disk shelf serial number of the shelf where this I/O module is seated.