sfu.adaptersuspendio events
sfu.adapterSuspendIO
- Severity
 - 
INFORMATIONAL
 - Description
 - 
This message occurs during a disk shelf firmware update on a disk shelf that cannot perform I/O while updating firmware. Typically, the shelves involved are bridge-based.
 - Corrective Action
 - 
I/O resumes automatically after the firmware update is complete.
 - Syslog Message
 - 
Suspending I/O to %s adapter %s for %d seconds while shelf firmware is updated.
 - Parameters
 - 
adapterType (STRING): Type of adapter that is updating firmware.
channelName (STRING): Name of the adapter on which shelves will be updating firmware.
minutes (INT): Amount of time that I/O will be suspended on the adapter. 
sfu.adapterSuspendIO.ndu
- Severity
 - 
INFORMATIONAL
 - Description
 - 
This message occurs during a disk shelf firmware update on a disk shelf that can perform I/O, but might have to suspend management requests while updating firmware. Typically, the shelves involved are DS12-ESAS, DS20-ESAS, DS4243.
 - Corrective Action
 - 
Suspended data traffic resumes automatically after the firmware update is complete.
 - Syslog Message
 - 
Suspending %s to %s adapter %s for %d seconds while shelf firmware is updated.
 - Parameters
 - 
dataTrafficType (STRING): Type of data traffic: SMP.
adapterType (STRING): Type of adapter that is updating firmware.
channelName (STRING): Name of the adapter on which shelves will be updating firmware.
minutes (INT): Amount of time that specified data traffic will be suspended on the adapter.