config.cfobothabmodule events
Collection of separate PDF docs
Creating your file...
config.CFObothABmodule
- Severity
-
ALERT
- Description
-
This message occurs when a disk shelf in a node is cabled for multipathing and the configuration does not support it. Multipathing means that the disk shelf is connected to one node through both disk shelf module A and module B. In HA configurations, multipathing is only supported if software disk ownership is being used and the storage shelf supports it.
- Corrective Action
-
For a standard HA configuration, identify the miscabled disk shelf and attach either module A or module B to the partner node. For a shared storage or multipathed HA, assign disk ownership to the partner node by using the "disk assign" command in Maintenance mode.
- Syslog Message
-
The disk shelf where disk %s resides is connected to this node through both disk shelf module A and module B; one of the modules must be connected to the partner node instead.
- Parameters
-
disk (STRING): Name of the disk that is cabled for multipathing.