Skip to main content
A newer release of this product is available.

cr.redir events

Contributors
Suggest changes

CR.Redir.File.Inaccessible

Deprecated

Deprecated as of Data ONTAP 9.6 because Infinite Volumes no longer exist.

Severity

NOTICE

Description

This message occurs when the data scanner skips an inode for which it cannot access the redirector file. This might be due to the namespace volume being offline.

Corrective Action

Bring the namespace volume back online using the "volume online" command. If the problem persists, retry the scan operation.

Syslog Message

The data file [%s] on data volume [%s] will be skipped by "Volume Check" because the corresponding redirector file on namespace volume [%s] on Vserver [%s] is not accessible.

Parameters

dataFilePath (STRING): Path of the data file that will get skipped.
dataVol (STRING): Name of the constituent data volume that hosts the data file.
nsVol (STRING): Name of the constituent namespace volume that hosts the redirector file.
vserver (STRING): Vserver hosting the constituent volumes.