Skip to main content
A newer release of this product is available.

dbs.drive events

Contributors
Suggest changes

dbs.drive

Severity

NOTICE

Description

This message occurs when a Distributed Block Store (DBS) event related to drive operations occurs. If the original DBS event specifies multiple drives, then an EMS event is generated for each drive.

Corrective Action

(None).

Syslog Message

A DBS event occurred, event %s, type %s, service %u, node %u/%s, drive %u/%s, eventID %u.

Parameters

evtMessage (STRING): Description of the DBS event, including context details.
evtType (STRING): Type of the original DBS event.
serviceID (INT): Service ID that identifies the associated DBS service. It is "0" if there is no associated service.
nodeID (INT): Node ID number of the associated node. It is "0" if there is no associated node.
nodeUuid (STRING): Generated Universal Unique Identifier (UUID) of the associated node. It displays zeroes if there is no associated node.
driveID (INT): Drive ID number of the associated drive. It is "0" if there is no associated drive.
driveUuid (STRING): Generated UUID of the associated drive. It displays zeroes if there is no associated drive.
evtID (INT): DBS event ID number.
evtDetails (STRING): Specific details of the DBS event. It displays as a string, in JSON format, or is empty.

dbs.drive.capacity.mismatch

Severity

ALERT

Description

This message occurs when Distributed Block Store (DBS) detects a drive capacity mismatch.

Corrective Action

Check capacity of drive against other DBS drives on the node. All drives are expected to be the same size.

Syslog Message

DBS has detected a drive capacity mismatch. Cluster fault node %u, node UUID %s, drives %s, drive UUIDs %s, type %s, fault ID %u, status %u. %s

Parameters

nodeID (INT): Node ID number of the associated node.
nodeUuid (STRING): Node UUID string of the associated node.
cfDriveIDs (STRING): IDs of the affected drives.
cfDriveUuids (STRING): UUIDs of the affected drives.
cfType (STRING): DBS cluster fault type of the associated object.
cfID (INT): DBS cluster fault ID number associated with the fault.
cfStatus (INT): Current status of the cluster fault. 1 = New (just reported), 2 = Existing (updated), 3 = Resolved (closed).
cfDetails (STRING): Details of the hardware mismatch.
cfExtSrc (STRING): DBS cluster fault externalSource label created by the CreateClusterFault API command and attached to the fault for testing purposes.