snapvault.sys events
Collection of separate PDF docs
Creating your file...
snapvault.sys.internal
- Severity
-
ERROR
- Description
-
This message occurs when SnapVault® encounters an internal error.
- Corrective Action
-
Turn off SnapVault and restart it.
- Syslog Message
-
An internal error occurred in SnapVault®: %s.
- Parameters
-
reason (STRING): Reason for the internal error.
snapvault.sys.upgrade
- Severity
-
ERROR
- Description
-
During initialization, SnapVault will attempt to update all the qtree metadata flags if necessary. This message is generated if there is insufficient memory to perform this operation.
- Corrective Action
-
Convert the qtrees manually or contact NetApp technical support to help.
- Syslog Message
-
Low on memory. Can't automatically convert snapvault qtrees right now, so backups will fail. Convert the qtrees manually or contact NetApp technical support to help.
- Parameters
-
(None).
snapvault.sys.vfilerOn
- Severity
-
INFORMATIONAL
- Description
-
This message occurs when SnapVault® is enabled on a vfiler during shutdown, where it is expected to be disabled.
- Corrective Action
-
None needed. This is for information only.
- Syslog Message
-
(None).
- Parameters
-
vfiler (STRING): Name of the vfiler.