A newer release of this product is available.
san.slmsupportcheckfailed events
Contributors
Suggest changes
Collection of separate PDF docs
Creating your file...
This may take a few minutes. Thanks for your patience.
Your file is ready
san.slmSupportCheckFailed
- Severity
-
ERROR
- Description
-
This message occurs during reboot when SAN capability is enabled, the cluster has more than 8 nodes and lun.reporting.nodes options is disabled. It leads to host instability as the number of paths exposed exceeds the threshold that the host stacks can handle.
- Corrective Action
-
Set the option "lun.reporting_nodes.enable" to "on" with the command "vserver options lun.reporting_nodes.enable on" and enable Selective LUN Map on existing maps with the command "lun mapping add-reporting-nodes -vserver * -path * -igroup * -local-nodes".
- Syslog Message
-
Clusters with more than 8 nodes must have SLM support enabled.
- Parameters
-
(None).