xfcvi.link events
Collection of separate PDF docs
Creating your file...
xfcvi.link.down
- Severity
-
NOTICE
- Description
-
This message occurs when the physical link of the Fibre Channel Virtual Interface (FC-VI) adapter goes down.
- Corrective Action
-
-
Ensure that the FC-VI link has not been tampered with. 2. Verify that the physical status of the FC-VI adapter is "Up" by using the command "metrocluster interconnect adapter show". 3. If the configuration includes fabric switches, ensure that they are properly cabled and configured.
-
- Syslog Message
-
(None).
- Parameters
-
alertId (STRING): Alert ID.
alertingResource (STRING): Alerting resource unique name.
alertingResourceName (STRING): Alerting resource name.
possibleEffect (STRING): Possible effect for link transition.
probableCause (STRING): Probable cause of the event.
probableCauseDescription (STRING): Probable cause description of the event.
additionalInfo (STRING): Any additional information for the event.
xfcvi.link.up
- Severity
-
NOTICE
- Description
-
This message occurs when the physical link of the Fibre Channel Virtual Interface (FC-VI) adapter comes up.
- Corrective Action
-
(None).
- Syslog Message
-
(None).
- Parameters
-
alertId (STRING): Alert ID.
alertingResource (STRING): Alerting resource unique name.