Skip to main content

dbs.node events

Contributors
Suggest changes

dbs.node.maint.mode.alert

Severity

ALERT

Description

This message occurs when Distributed Block Store (DBS) detects a node with a maintenance mode failure.

Corrective Action

Contact NetApp technical support.

Syslog Message

DBS has detected a node with a maintenance mode failure. Cluster fault node %u, node UUID %s, type %s, fault ID %u, status %u. %s

Parameters

nodeID (INT): Node ID number of the associated node.
nodeUuid (STRING): Node UUID string of the associated node.
cfType (STRING): DBS cluster fault type of the associated object.
cfID (INT): DBS cluster fault ID number associated with the fault.
cfStatus (INT): Current status of the cluster fault. 1 = New (just reported), 2 = Existing (updated), 3 = Resolved (closed).
cfDetails (STRING): Details of the node in maintenance mode.
cfExtSrc (STRING): DBS cluster fault externalSource label created by the CreateClusterFault API command and attached to the fault for testing purposes.

dbs.node.maint.mode.error

Severity

ERROR

Description

This message occurs when Distributed Block Store (DBS) detects a node is in maintenance mode.

Corrective Action

Disable maintenance mode when maintenance is complete.

Syslog Message

DBS has detected a node is in maintenance mode. Cluster fault node %u, node UUID %s, type %s, fault ID %u, status %u. %s

Parameters

nodeID (INT): Node ID number of the associated node.
nodeUuid (STRING): Node UUID string of the associated node.
cfType (STRING): DBS cluster fault type of the associated object.
cfID (INT): DBS cluster fault ID number associated with the fault.
cfStatus (INT): Current status of the cluster fault. 1 = New (just reported), 2 = Existing (updated), 3 = Resolved (closed).
cfDetails (STRING): Details of the node in maintenance mode.
cfExtSrc (STRING): DBS cluster fault externalSource label created by the CreateClusterFault API command and attached to the fault for testing purposes.

dbs.node.offline

Severity

ALERT

Description

This message occurs when Distributed Block Store (DBS) detects the Cluster Master cannot communicate with the master service on a node.

Corrective Action

Check for network connectivity issues and hardware errors.

Syslog Message

DBS has detected the Cluster Master cannot communicate with the master service on a node. Cluster fault node %u, node UUID %s, type %s, fault ID %u, status %u. %s

Parameters

nodeID (INT): Node ID number of the associated node.
nodeUuid (STRING): Node UUID string of the associated node.
cfType (STRING): DBS cluster fault type of the associated object.
cfID (INT): DBS cluster fault ID number associated with the fault.
cfStatus (INT): Current status of the cluster fault. 1 = New (just reported), 2 = Existing (updated), 3 = Resolved (closed).
cfDetails (STRING): Details of the node offline.
cfExtSrc (STRING): DBS cluster fault externalSource label created by the CreateClusterFault API command and attached to the fault for testing purposes.