dfu.badbridgeshelfconfig events
Contributors
Suggest changes
dfu.badBridgeShelfConfig
- Severity
-
ERROR
- Description
-
This message occurs when the disk firmware update aborts because it cannot contact the two peer FC-to-SAS bridges.
- Corrective Action
-
Make sure that the storage controller is correctly cabled to the two peer FC-to-SAS bridges and that the bridges are correctly cabled to the SAS disk shelves. Then retry the 'disk_fw_update' command.
- Syslog Message
-
Error contacting two peer FC-to-SAS bridges. Unable to download firmware to disk %s [%s %s %s] S/N [%s].
- Parameters
-
diskName (STRING): Name of the disk.
vendorName (STRING): Vendor name of the disk.
productId (STRING): Product ID of the disk.
fwVersion (STRING): Firmware version of the disk.
serialno (STRING): Serial number of the disk.