sfu.badbridgeshelfconfig events
Contributors
Suggest changes
sfu.badBridgeShelfConfig
- Severity
-
ALERT
- Description
-
This message occurs when the disk shelf firmware update aborts because it cannot contact the two peer FC-to-SAS bridges.
- Corrective Action
-
Make sure that the storage controller is correctly cabled to the two peer FC-to-SAS bridges and that the bridges are correctly cabled to the SAS disk shelves. Then retry the (advanced privilege) "storage shelf firmware update" command.
- Syslog Message
-
Firmware update aborted on disk shelf %s.shelf%d module %s. Unable to contact two peer FC-to-SAS bridges.
- Parameters
-
channelName (STRING): Name of the adapter port or switch port of the disk shelf that aborted the firmware update.
shelfId (INT): ID of the disk shelf that aborted the firmware update.
module (STRING): Module that aborted the firmware update.