monitor.fan events
monitor.fan.critical
- Severity
 - 
EMERGENCY
 - Description
 - 
This message occurs when one or more main unit fans have failed. The system cannot continue to operate.
 - Corrective Action
 - 
Replace the failed fans.
 - Syslog Message
 - 
%s
 - Parameters
 - 
report (STRING): Report indicating the critical state.
object_type (STRING): Type of resource object under notification. For this EMS, the object_type will always be NODE.
object_uuid (STRING): UUID of the resource object. For this EMS, the UUID will be of the node. 
monitor.fan.failed
- Severity
 - 
ALERT
 - Description
 - 
This message occurs when one or more main unit fans have failed. The system remains operational. If the condition persists too long, an automatic shutdown for overtemperature might occur.
 - Corrective Action
 - 
Reseat the failed fans. If the error persists, replace them.
 - Syslog Message
 - 
%s
 - Parameters
 - 
report (STRING): Report indicating the failed fans.
object_type (STRING): Type of resource object under notification. For this EMS, the object_type will always be NODE.
object_uuid (STRING): UUID of the resource object. For this EMS, the UUID will be of the node. 
monitor.fan.ok
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when a previously failed main unit fan has been restarted.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
%s
 - Parameters
 - 
report (STRING): Report indicating that the failed fans have restarted.
 
monitor.fan.warning
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when one or more fans are in a warning state.
 - Corrective Action
 - 
Replace the indicated fans to avoid overheating.
 - Syslog Message
 - 
%s
 - Parameters
 - 
report (STRING): Report indicating the warning level.
object_type (STRING): Type of resource object under notification. For this EMS, the object_type will always be NODE.
object_uuid (STRING): UUID of the resource object. For this EMS, the UUID will be of the node.