Skip to main content
ONTAP EMS reference

cifs.db events

Suggest changes

cifs.db.v2.exists

Severity

ERROR

Description

This message occurs when a CIFS server fails to be removed on the secondary site for an SVM in a MetroCluster configuration or SVM DR setup. The stale CIF server might cause issues when it is reprovisioned.

Corrective Action

If this is a SnapMirror or MetroCluster environment, run the "snapmirror resync" command or the "metrocluster vserver resync" command respectively to resynchronize the Vserver configuration.

Syslog Message

Stale CIFS server exists and may cause issues when reprovisioned. Vserver: %s Cifs Server: %s Error: %s.

Parameters

reason (STRING): Reason for the failure.
Vservername (STRING): Name of the Vserver.
cifsservername (STRING): Name of the cifs server.