ctrl.link events
ctrl.link.degraded
- Severity
-
ERROR
- Description
-
This message occurs when the software detects either symbol errors or out-of-sequence errors on HA interconnect links.
- Corrective Action
-
If possible, replace the degraded interconnect cables and reenable automatic switchover by using the "options -option-name rdma.link_monitor -option-value on" command. If the problem persists after replacing both interconnect cables, replace the interconnect hardware on both nodes.
- Syslog Message
-
Link errors detected on card in slot %d. Number of symbol errors (Port1:Port2): %d:%d; Number of OOS errors(RQ:SQ): %d:%d.
- Parameters
-
slot (INT): Slot number of the HA Interconnect device.
sym_err1 (INT): Symbol errors on the first port.
sym_err2 (INT): Symbol errors on the second port.
rq_oos (INT): Out-of-sequence errors on the receive queue.
sq_oos (INT): Out-of-sequence errors on the send queue.
ctrl.link.switchover
- Severity
-
INFORMATIONAL
- Description
-
This message occurs when the software initiates a switchover of the active interconnect link, which has been declared degraded.
- Corrective Action
-
If possible, replace the degraded interconnect cable and reenable the automatic switchover by using the "options -option-name rdma.link_monitor -option-value on" command. If the problem persists after replacing both the interconnect cables, replace the interconnect hardware on both nodes.
- Syslog Message
-
Link switchover initiated to switch active interconnect link %s.
- Parameters
-
degraded_port_name (STRING): Port name of the degraded link that is being switched from.