disk.uid events
disk.uid.changed
- Severity
-
NOTICE
- Description
-
This message occurs when a SCSI (Small Computer System Interface) INQUIRY command done during a disk drive initialization sequence finds different data in the INQUIRY response for page 0x83. The unique id (UID) derived from this information has changed unexpectedly.
- Corrective Action
-
Locate the failed disk drive by looking for a disk drive whose amber LED fault light is lit. Replace the disk drive.
- Syslog Message
-
Disk %s has unexpectedly changed its unique ID. vendor:%s product:%s serial_number:%s
- Parameters
-
diskName (STRING): Name of the disk that had the UID change.
disk_vendor_id (STRING): Vendor name of the disk that had the UID change.
disk_product_id (STRING): Product name of the disk that had the UID change.
disk_serialno (STRING): Serial number of the disk that had the UID change.