ha.panicinfosznotok events
ha.panicInfoSzNotOk
- Severity
-
NOTICE
- Description
-
This message occurs when the size of the panic information received from the high-availability (HA) partner is not equal to the expected panic information size. The receiving node will discard this panic information message. A takeover might still occur if the local node detects that its HA partner is down by other means, and takeover of the panicking node is allowed.
- Corrective Action
-
(None).
- Syslog Message
-
Panic information message received from the HA partner is the wrong size. Expected size: %u. Received size: %u. Partner name: %s. Partner system ID: %llu.
- Parameters
-
expected_size (LONGINT): Expected size of the panic information.
received_size (LONGINT): Received size of the panic information.
partner_name (STRING): Name of the HA partner.
partner_systemid (LONGINT): System ID of the HA partner.