raid.diskadd events
raid.diskadd.abort
- Severity
-
ERROR
- Description
-
This message occurs when the system aborts the addition of disks to an aggregate.
- Corrective Action
-
Use the reason provided to determine an action from the following list: - Change in raidgroup size: Retry adding disks to the volume. - One of the target plexes has failed: Delete the failed plex. Use the "storage aggregate plex delete" command. When the failed plex is removed and the aggregate state appears as "unmirrored", retry adding disks to the volume. - For further information or assistance, contact NetApp technical support.
- Syslog Message
-
Addition of disks to %s %s%s aborted %s.
- Parameters
-
vol_type (STRING): Volume type.
owner (STRING): Owner of the aggregate.
vol (STRING): Name of the aggregate.
reason (STRING): Reason the disk addition was aborted.
raid.diskadd.add.abort
- Severity
-
ERROR
- Description
-
This message occurs when the addition of disks to an aggregate is aborted due to a detected disk failure.
- Corrective Action
-
Retry adding disks to the aggregate. If disk list was specified for addition, replace the failed disk with a good disk in the list.
- Syslog Message
-
Addition of disks to %s %s%s aborted due to failure of %s.
- Parameters
-
vol_type (STRING): Volume type.
owner (STRING): Owner of the affected aggregate.
vol (STRING): Name of the aggregate.
disk_info (STRING): Information about the disk object, including disk name, path, shelf, bay, serial number, vendor, model, RPM, and carrier serial number.
shelf (STRING): Identifier of the disk shelf where the disk is located.
bay (STRING): Disk bay within the shelf where the disk is located.
vendor (STRING): Name of the disk drive vendor.
model (STRING): String representing the name of the model of the disk drive.
firmware_revision (STRING): Firmware revision number of the disk.
serialno (STRING): Serial number of the disk.
disk_type (INT): Type of disk drive.
disk_rpm (STRING): Rotational speed of the disk, in RPM.
carrier (STRING): Unique ID of the carrier in which the disk is installed.
site (STRING): For a MetroCluster(tm) configuration, indicates the site {Local|Remote} where the disk is located. For non-MetroCluster configurations, site is 'Local'.
raid.diskadd.create.abort
- Severity
-
ERROR
- Description
-
This message occurs when the creation of a an aggregate is aborted due to a detected disk failure.
- Corrective Action
-
Retry the aggregate creation. If disk list was specified for creation, replace the failed disk with a good disk in the list.
- Syslog Message
-
Creation of %s %s%s aborted due to failure of %s.
- Parameters
-
vol_type (STRING): Volume type.
owner (STRING): Owner of the affected aggregate.
vol (STRING): Name of the aggregate.
disk_info (STRING): Information about the disk object, including disk name, path, shelf, bay, serial number, vendor, model, RPM, and carrier serial number.
shelf (STRING): Identifier of the disk shelf where the disk is located.
bay (STRING): Disk bay within the shelf where the disk is located.
vendor (STRING): Name of the disk drive vendor.
model (STRING): String representing the name of the model of the disk drive.
firmware_revision (STRING): Firmware revision number of the disk.
serialno (STRING): Serial number of the disk.
disk_type (INT): Type of disk drive.
disk_rpm (STRING): Rotational speed of the disk, in RPM.
carrier (STRING): Unique ID of the carrier in which the disk is installed.
site (STRING): For a MetroCluster(tm) configuration, indicates the site {Local|Remote} where the disk is located. For non-MetroCluster configurations, site is 'Local'.