san.lifspernodelimit events
san.LifsPerNodeLimit
- Severity
-
ERROR
- Description
-
This message occurs in MetroCluster(tm) configurations on clustered Data ONTAP® systems, when Data ONTAP cannot replicate a SAN or NVMe logical interface (LIF) in the destination cluster due to the LIF limits per node per Vserver.
- Corrective Action
-
Make sure all the nodes are online by running "storage failover show" command on both the clusters. If a node is taken-over by its HA partner, giveback the node using "storage failover giveback -ofnode <name_of_node_to_giveback>". Once the nodes are online and healthy, run the "metrocluster vserver resync -vserver <vserver_name>" from the source cluster. Verify the vserver's configuration-state is healthy using "metrocluster vserver show -vserver <vserver_name>" command. Contact technical support for assistance if configuration-state of the vserver does not change to healthy.
- Syslog Message
-
Metrocluster does not support more than %s %s LIFs per node per Vserver.
- Parameters
-
limit (STRING): LIF limit supported on Metrocluster
data_protocol (STRING): Data protocol of the LIF that exceeds the LIF per node per Vserver limit.