se.gatherer events
se.gatherer.done
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when Single Instance Storage (SIS) auto gathering scanner completed on the auto adaptive volume.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Auto adaptive gathering scanner completed for %s %s %s %s %s.
 - Parameters
 - 
type (STRING): Type of object (volume or aggregate).
owner (STRING): Volume owner.
vol (STRING): Volume name.
app (STRING): Application UUID.
volident (STRING): To uniquely identify the volume in cases where the volume name itself is insufficient. 
se.gatherer.skip
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when Single Instance Storage (SIS) auto adaptive gathering scanner could not be triggered on the volume post migration.
 - Corrective Action
 - 
Run "volume efficiency start" command with "-scan-old-data" to manually start the auto adaptive gathering scanner.
 - Syslog Message
 - 
Auto adaptive gathering scanner on volume %s%s could not be triggered for %s due to error: %s.
 - Parameters
 - 
vol (STRING): Name of the volume
volident (STRING): To uniquely identify the volume in cases where volume name itself is insufficient.
trigger_type (STRING): Type of the trigger that was attempted.