What happens when a link failure occurs
Suggest changes
ONTAP monitors a link's usage periodically. The ONTAP response to a link failure differs depending on where the failure occurs.
The following table shows what occurs if there is a failure in a fabric-attached configuration:
If a failure occurs in the link between the… | Then… |
---|---|
ONTAP system and the switch |
ONTAP receives notification immediately and sends traffic to the other path immediately. |
Switch and the storage array |
ONTAP is not immediately aware that there is a link failure because the link is still established between the ONTAP system and the switch. ONTAP becomes aware that there is a failure when the I/O times out. ONTAP retries three times to send the traffic on the original path, then it fails over the traffic to the other path. |