Skip to main content
ONTAP MetroCluster

Verifying the storage configuration

Contributors netapp-thomi netapp-pcarriga

You must confirm that all storage is visible from the surviving nodes.

Steps
  1. Confirm that all storage components at the disaster site are the same in quantity and type at the surviving site.

    The surviving site and disaster site should have the same number of disk shelf stacks, disk shelves, and disks. In a bridge-attached or fabric-attached MetroCluster configuration, the sites should have the same number of FC-to-SAS bridges.

  2. Confirm that all disks that have been replaced at the disaster site are unowned:

    run local disk show-n

    Disks should appear as being unowned.

  3. If no disks were replaced, confirm that all disks are present:

    disk show