Downloading and installing the Cisco FC switch NX-OS software
You must download the switch operating system file and RCF file to each switch in the MetroCluster fabric configuration.
This task requires file transfer software, such as FTP, TFTP, SFTP, or SCP, to copy the files to the switches.
These steps must be repeated on each of the FC switches in the MetroCluster fabric configuration.
You must use the supported switch software version.
The outputs shown are for Cisco IP switches; however, these steps are also applicable for Cisco FC switches. |
-
Download the supported NX-OS software file.
-
Copy the switch software to the switch:
copy sftp://root@server-ip-address/tftpboot/NX-OS-file-name bootflash: vrf management
In this example, the
nxos.7.0.3.I4.6.bin
file is copied from SFTP server 10.10.99.99 to the local bootflash:IP_switch_A_1# copy sftp://root@10.10.99.99/tftpboot/nxos.7.0.3.I4.6.bin bootflash: vrf management root@10.10.99.99's password: password sftp> progress Progress meter enabled sftp> get /tftpboot/nxos.7.0.3.I4.6.bin /bootflash/nxos.7.0.3.I4.6.bin Fetching /tftpboot/nxos.7.0.3.I4.6.bin to /bootflash/nxos.7.0.3.I4.6.bin /tftpboot/nxos.7.0.3.I4.6.bin 100% 666MB 7.2MB/s 01:32 sftp> exit Copy complete, now saving to disk (please wait)...
-
Verify on each switch that the switch NX-OS files are present in each switch's bootflash directory:
dir bootflash
The following example shows that the files are present on
IP_switch_A_1
:IP_switch_A_1# dir bootflash: . . . 698629632 Jun 13 21:37:44 2017 nxos.7.0.3.I4.6.bin . . . Usage for bootflash://sup-local 1779363840 bytes used 13238841344 bytes free 15018205184 bytes total IP_switch_A_1#
-
Install the switch software:
install all system bootflash:nxos.version-number.bin kickstart bootflash:nxos.version-kickstart-number.bin
IP_switch_A_1# install all system bootflash:nxos.7.0.3.I4.6.bin kickstart bootflash:nxos.7.0.3.I4.6.bin Installer will perform compatibility check first. Please wait. Verifying image bootflash:/nxos.7.0.3.I4.6.bin for boot variable "kickstart". [####################] 100% -- SUCCESS Verifying image bootflash:/nxos.7.0.3.I4.6.bin for boot variable "system". [####################] 100% -- SUCCESS Performing module support checks. [####################] 100% -- SUCCESS Verifying image type. [####################] 100% -- SUCCESS Extracting "system" version from image bootflash:/nxos.7.0.3.I4.6.bin. [####################] 100% -- SUCCESS Extracting "kickstart" version from image bootflash:/nxos.7.0.3.I4.6.bin. [####################] 100% -- SUCCESS ...
The switch reboot automatically after the switch software has installed.
-
Wait for the switch to reload and then log in to the switch.
After the switch has rebooted the login prompt is displayed:
User Access Verification IP_switch_A_1 login: admin Password: Cisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (C) 2002-2017, Cisco and/or its affiliates. All rights reserved. . . . MDP database restore in progress. IP_switch_A_1# The switch software is now installed.
-
Verify that the switch software has been installed:
show version
The following example shows the output:
IP_switch_A_1# show version Cisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (C) 2002-2017, Cisco and/or its affiliates. All rights reserved. . . . Software BIOS: version 04.24 NXOS: version 7.0(3)I4(6) **<<< switch software version** BIOS compile time: 04/21/2016 NXOS image file is: bootflash:///nxos.7.0.3.I4.6.bin NXOS compile time: 3/9/2017 22:00:00 [03/10/2017 07:05:18] Hardware cisco Nexus 3132QV Chassis Intel(R) Core(TM) i3- CPU @ 2.50GHz with 16401416 kB of memory. Processor Board ID FOC20123GPS Device name: A1 bootflash: 14900224 kB usb1: 0 kB (expansion flash) Kernel uptime is 0 day(s), 0 hour(s), 1 minute(s), 49 second(s) Last reset at 403451 usecs after Mon Jun 10 21:43:52 2017 Reason: Reset due to upgrade System version: 7.0(3)I4(1) Service: plugin Core Plugin, Ethernet Plugin IP_switch_A_1#
-
Repeat these steps on the remaining three FC switches in the MetroCluster fabric configuration.