You can test failure scenarios to confirm the correct operation of the MetroCluster configuration.

Verifying negotiated switchover

You can test the negotiated (planned) switchover operation to confirm uninterrupted data availability.

About this task

This test validates that data availability is not affected (except for Microsoft Server Message Block (SMB) and Solaris Fibre Channel protocols) by switching the cluster over to the second data center.

This test should take about 30 minutes.

This procedure has the following expected results:

  • The metrocluster switchover command will present a warning prompt.

    If you respond yes to the prompt, the site the command is issued from will switch over the partner site.

For MetroCluster IP configurations:

  • For ONTAP 9.4 and earlier:

    • Mirrored aggregates will become degraded after the negotiated switchover.

  • For ONTAP 9.5 and later:

    • Mirrored aggregates will remain in normal state if the remote storage is accessible.

    • Mirrored aggregates will become degraded after the negotiated switchover if access to the remote storage is lost.

  • For ONTAP 9.8 and later:

    • Unmirrored aggregates that are located at the disaster site will become unavailable if access to the remote storage is lost. This might lead to a controller outage.

Steps
  1. Confirm that all nodes are in the configured state and normal mode:

    metrocluster node show

    cluster_A::>  metrocluster node show
    
    Cluster                        Configuration State    Mode
    ------------------------------ ---------------------- ------------------------
     Local: cluster_A               configured             normal
    Remote: cluster_B               configured             normal
  2. Begin the switchover operation:

    metrocluster switchover

    cluster_A::> metrocluster switchover
    Warning: negotiated switchover is about to start. It will stop all the data Vservers on cluster "cluster_B" and
    automatically re-start them on cluster "`cluster_A`". It will finally gracefully shutdown cluster "cluster_B".
  3. Confirm that the local cluster is in the configured state and switchover mode:

    metrocluster node show

    cluster_A::>  metrocluster node show
    
    Cluster                        Configuration State    Mode
    ------------------------------ ---------------------- ------------------------
    Local: cluster_A                configured             switchover
    Remote: cluster_B               not-reachable          -
                  configured             normal
  4. Confirm that the switchover operation was successful:

    metrocluster operation show

    cluster_A::>  metrocluster operation show
    
    cluster_A::> metrocluster operation show
      Operation: switchover
          State: successful
     Start Time: 2/6/2016 13:28:50
       End Time: 2/6/2016 13:29:41
         Errors: -
  5. Use the vserver show and network interface show commands to verify that DR SVMs and LIFs have come online.

Verifying healing and manual switchback

You can test the healing and manual switchback operations to verify that data availability is not affected (except for SMB and Solaris FC configurations) by switching back the cluster to the original data center after a negotiated switchover.

About this task

This test should take about 30 minutes.

The expected result of this procedure is that services should be switched back to their home nodes.

Steps
  1. Verify that healing is completed:

    metrocluster node show

    The following example shows the successful completion of the command:

    cluster_A::> metrocluster node show
    DR                               Configuration  DR
    Group Cluster Node               State          Mirroring Mode
    ----- ------- ------------------ -------------- --------- --------------------
    1     cluster_A
                  node_A_1         configured     enabled   heal roots completed
          cluster_B
                  node_B_2         unreachable    -         switched over
    42 entries were displayed.metrocluster operation show
  2. Verify that all aggregates are mirrored:

    storage aggregate show

    The following example shows that all aggregates have a RAID Status of mirrored:

    cluster_A::> storage aggregate show
    cluster Aggregates:
    Aggregate Size     Available Used% State   #Vols  Nodes       RAID Status
    --------- -------- --------- ----- ------- ------ ----------- ------------
    data_cluster
                4.19TB    4.13TB    2% online       8 node_A_1    raid_dp,
                                                                  mirrored,
                                                                  normal
    root_cluster
               715.5GB   212.7GB   70% online       1 node_A_1    raid4,
                                                                  mirrored,
                                                                  normal
    cluster_B Switched Over Aggregates:
    Aggregate Size     Available Used% State   #Vols  Nodes       RAID Status
    --------- -------- --------- ----- ------- ------ ----------- ------------
    data_cluster_B
                4.19TB    4.11TB    2% online       5 node_A_1    raid_dp,
                                                                  mirrored,
                                                                  normal
    root_cluster_B    -         -     - unknown      - node_A_1   -
  3. Boot the nodes from the disaster site.

  4. Check the status of switchback recovery:

    metrocluster node show

    cluster_A::> metrocluster node show
    DR                               Configuration  DR
    Group Cluster Node               State          Mirroring Mode
    ----- ------- ------------------ -------------- --------- --------------------
    1     cluster_A
                 node_A_1            configured     enabled   heal roots completed
          cluster_B
                 node_B_2            configured     enabled   waiting for switchback
                                                              recovery
    2 entries were displayed.
  5. Perform the switchback:

    metrocluster switchback

    cluster_A::> metrocluster switchback
    [Job 938] Job succeeded: Switchback is successful.Verify switchback
  6. Confirm the status of the nodes:

    metrocluster node show

    cluster_A::> metrocluster node show
    DR                               Configuration  DR
    Group Cluster Node               State          Mirroring Mode
    ----- ------- ------------------ -------------- --------- --------------------
    1     cluster_A
                  node_A_1         configured     enabled   normal
          cluster_B
                  node_B_2         configured     enabled   normal
    
    2 entries were displayed.
  7. Confirm the status:

    metrocluster operation show

    The output should show a successful state.

    cluster_A::> metrocluster operation show
      Operation: switchback
          State: successful
     Start Time: 2/6/2016 13:54:25
       End Time: 2/6/2016 13:56:15
         Errors: -

Loss of a single FC-to-SAS bridge

You can test the failure of a single FC-to-SAS bridge to make sure there is no single point of failure.

About this task

This test should take about 15 minutes.

This procedure has the following expected results:

  • Errors should be generated as the bridge is switched off.

  • No failover or loss of service should occur.

  • Only one path from the controller module to the drives behind the bridge is available.

Note Beginning with ONTAP 9.8, the storage bridge command is replaced with system bridge. The following steps show the storage bridge command, but if you are running ONTAP 9.8 or later, the system bridge command is preferred.
Steps
  1. Turn off the power supplies of the bridge.

  2. Confirm that the bridge monitoring indicates an error:

    storage bridge show

    cluster_A::> storage bridge show
    
                                                                Is        Monitor
    Bridge     Symbolic Name Vendor  Model     Bridge WWN       Monitored Status
    ---------- ------------- ------- --------- ---------------- --------- -------
    ATTO_10.65.57.145
    	     bridge_A_1    Atto    FibreBridge 6500N
                                               200000108662d46c true      error
  3. Confirm that the drives behind the bridge are available with a single path:

    storage disk error show

    cluster_A::> storage disk error show
    Disk             Error Type        Error Text
    ---------------- ----------------- --------------------------------------------
    1.0.0            onedomain         1.0.0 (5000cca057729118): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.
    1.0.1            onedomain         1.0.1 (5000cca057727364): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.
    1.0.2            onedomain         1.0.2 (5000cca05772e9d4): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.
    ...
    1.0.23           onedomain         1.0.23 (5000cca05772e9d4): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.

Verifying operation after power line disruption

You can test the MetroCluster configuration's response to the failure of a PDU.

About this task

The best practice is for each power supply unit (PSU) in a component to be connected to separate power supplies. If both PSUs are connected to the same power distribution unit (PDU) and an electrical disruption occurs, the site could down or a complete shelf might become unavailable. Failure of one power line is tested to confirm that there is no cabling mismatch that could cause a service disruption.

This test should take about 15 minutes.

This test requires turning off power to all left-hand PDUs and then all right-hand PDUs on all of the racks containing the MetroCluster components.

This procedure has the following expected results:

  • Errors should be generated as the PDUs are disconnected.

  • No failover or loss of service should occur.

Steps
  1. Turn off the power of the PDUs on the left-hand side of the rack containing the MetroCluster components.

  2. Monitor the result on the console:

    system environment sensors show -state fault

    storage shelf show -errors

    cluster_A::> system environment sensors show -state fault
    
    Node Sensor 			State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
    ---- --------------------- ------ ----------- -------- -------- ------- -------
    node_A_1
    		PSU1 			fault
    							PSU_OFF
    		PSU1 Pwr In OK 	fault
    							FAULT
    node_A_2
    		PSU1 			fault
    							PSU_OFF
    		PSU1 Pwr In OK 	fault
    							FAULT
    4 entries were displayed.
    
    cluster_A::> storage shelf show -errors
        Shelf Name: 1.1
         Shelf UID: 50:0a:09:80:03:6c:44:d5
     Serial Number: SHFHU1443000059
    
    Error Type          Description
    ------------------  ---------------------------
    Power               Critical condition is detected in storage shelf power supply unit "1". The unit might fail.Reconnect PSU1
  3. Turn the power back on to the left-hand PDUs.

  4. Make sure that ONTAP clears the error condition.

  5. Repeat the previous steps with the right-hand PDUs.

Verifying operation after a switch fabric failure

You can disable a switch fabric to show that data availability is not affected by the loss.

About this task

This test should take about 15 minutes.

The expected result of this procedure is that disabling a fabric results in all cluster interconnect and disk traffic flowing to the other fabric.

In the examples shown, switch fabric 1 is disabled. This fabric consists of two switches, one at each MetroCluster site:

  • FC_switch_A_1 on cluster_A

  • FC_switch_B_1 on cluster_B

Steps
  1. Disable connectivity to one of the two switch fabrics in the MetroCluster configuration:

    1. Disable the first switch in the fabric:

      switchdisable

      FC_switch_A_1::> switchdisable
    2. Disable the second switch in the fabric:

      switchdisable

      FC_switch_B_1::> switchdisable
  2. Monitor the result on the console of the controller modules.

    You can use the following commands to check the cluster nodes to make sure that all data is still being served. The command output shows missing paths to disks. This is expected.

    • vserver show

    • network interface show

    • aggr show

    • system node runnodename-command storage show disk -p

    • storage disk error show

  3. Reenable connectivity to one of the two switch fabrics in the MetroCluster configuration:

    1. Reenable the first switch in the fabric:

      switchenable

      FC_switch_A_1::> switchenable
    2. Reenable the second switch in the fabric:

      switchenable

      FC_switch_B_1::> switchenable
  4. Wait at least 10 minutes and then repeat the above steps on the other switch fabric.

Verifying operation after loss of a single storage shelf

You can test the failure of a single storage shelf to verify that there is no single point of failure.

About this task

This procedure has the following expected results:

  • An error message should be reported by the monitoring software.

  • No failover or loss of service should occur.

  • Mirror resynchronization starts automatically after the hardware failure is restored.

Steps
  1. Check the storage failover status:

    storage failover show

    cluster_A::> storage failover show
    
    Node           Partner        Possible State Description
    -------------- -------------- -------- -------------------------------------
    node_A_1       node_A_2       true     Connected to node_A_2
    node_A_2       node_A_1       true     Connected to node_A_1
    2 entries were displayed.
  2. Check the aggregate status:

    storage aggregate show

    cluster_A::> storage aggregate show
    
    cluster Aggregates:
    Aggregate     Size Available Used% State   #Vols  Nodes            RAID Status
    --------- -------- --------- ----- ------- ------ ---------------- ------------
    node_A_1data01_mirrored
                4.15TB    3.40TB   18% online       3 node_A_1       raid_dp,
                                                                       mirrored,
                                                                       normal
    node_A_1root
               707.7GB   34.29GB   95% online       1 node_A_1       raid_dp,
                                                                       mirrored,
                                                                       normal
    node_A_2_data01_mirrored
                4.15TB    4.12TB    1% online       2 node_A_2       raid_dp,
                                                                       mirrored,
                                                                       normal
    node_A_2_data02_unmirrored
                2.18TB    2.18TB    0% online       1 node_A_2       raid_dp,
                                                                       normal
    node_A_2_root
               707.7GB   34.27GB   95% online       1 node_A_2       raid_dp,
                                                                       mirrored,
                                                                       normal
  3. Verify that all data SVMs and data volumes are online and serving data:

    vserver show -type data

    network interface show -fields is-home false

    volume show !vol0,!MDV*

    cluster_A::> vserver show -type data
    
    cluster_A::> vserver show -type data
                                   Admin      Operational Root
    Vserver     Type    Subtype    State      State       Volume     Aggregate
    ----------- ------- ---------- ---------- ----------- ---------- ----------
    SVM1        data    sync-source           running     SVM1_root  node_A_1_data01_mirrored
    SVM2        data    sync-source	          running     SVM2_root  node_A_2_data01_mirrored
    
    cluster_A::> network interface show -fields is-home false
    There are no entries matching your query.
    
    cluster_A::> volume show !vol0,!MDV*
    Vserver   Volume       Aggregate    State      Type       Size  Available Used%
    --------- ------------ ------------ ---------- ---- ---------- ---------- -----
    SVM1
              SVM1_root
                           node_A_1data01_mirrored
                                        online     RW         10GB     9.50GB    5%
    SVM1
              SVM1_data_vol
                           node_A_1data01_mirrored
                                        online     RW         10GB     9.49GB    5%
    SVM2
              SVM2_root
                           node_A_2_data01_mirrored
                                        online     RW         10GB     9.49GB    5%
    SVM2
              SVM2_data_vol
                           node_A_2_data02_unmirrored
                                        online     RW          1GB    972.6MB    5%
  4. Identify a shelf in Pool 1 for node node_A_2 to power off to simulate a sudden hardware failure:

    storage aggregate show -r -node node-name !*root

    The shelf you select must contain drives that are part of a mirrored data aggregate.

    In the following example, shelf ID 31 is selected to fail.

    cluster_A::> storage aggregate show -r -node node_A_2 !*root
    Owner Node: node_A_2
     Aggregate: node_A_2_data01_mirrored (online, raid_dp, mirrored) (block checksums)
      Plex: /node_A_2_data01_mirrored/plex0 (online, normal, active, pool0)
       RAID Group /node_A_2_data01_mirrored/plex0/rg0 (normal, block checksums)
                                                                  Usable Physical
         Position Disk                        Pool Type     RPM     Size     Size Status
         -------- --------------------------- ---- ----- ------ -------- -------- ----------
         dparity  2.30.3                       0   BSAS    7200  827.7GB  828.0GB (normal)
         parity   2.30.4                       0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.6                       0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.8                       0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.5                       0   BSAS    7200  827.7GB  828.0GB (normal)
    
      Plex: /node_A_2_data01_mirrored/plex4 (online, normal, active, pool1)
       RAID Group /node_A_2_data01_mirrored/plex4/rg0 (normal, block checksums)
                                                                  Usable Physical
         Position Disk                        Pool Type     RPM     Size     Size Status
         -------- --------------------------- ---- ----- ------ -------- -------- ----------
         dparity  1.31.7                       1   BSAS    7200  827.7GB  828.0GB (normal)
         parity   1.31.6                       1   BSAS    7200  827.7GB  828.0GB (normal)
         data     1.31.3                       1   BSAS    7200  827.7GB  828.0GB (normal)
         data     1.31.4                       1   BSAS    7200  827.7GB  828.0GB (normal)
         data     1.31.5                       1   BSAS    7200  827.7GB  828.0GB (normal)
    
     Aggregate: node_A_2_data02_unmirrored (online, raid_dp) (block checksums)
      Plex: /node_A_2_data02_unmirrored/plex0 (online, normal, active, pool0)
       RAID Group /node_A_2_data02_unmirrored/plex0/rg0 (normal, block checksums)
                                                                  Usable Physical
         Position Disk                        Pool Type     RPM     Size     Size Status
         -------- --------------------------- ---- ----- ------ -------- -------- ----------
         dparity  2.30.12                      0   BSAS    7200  827.7GB  828.0GB (normal)
         parity   2.30.22                      0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.21                      0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.20                      0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.14                      0   BSAS    7200  827.7GB  828.0GB (normal)
    15 entries were displayed.
  5. Physically power off the shelf that you selected.

  6. Check the aggregate status again:

    storage aggregate show

    storage aggregate show -r -node node_A_2 !*root

    The aggregate with drives on the powered-off shelf should have a “degraded” RAID status, and drives on the affected plex should have a “failed” status, as shown in the following example:

    cluster_A::> storage aggregate show
    Aggregate     Size Available Used% State   #Vols  Nodes            RAID Status
    --------- -------- --------- ----- ------- ------ ---------------- ------------
    node_A_1data01_mirrored
                4.15TB    3.40TB   18% online       3 node_A_1       raid_dp,
                                                                       mirrored,
                                                                       normal
    node_A_1root
               707.7GB   34.29GB   95% online       1 node_A_1       raid_dp,
                                                                       mirrored,
                                                                       normal
    node_A_2_data01_mirrored
                4.15TB    4.12TB    1% online       2 node_A_2       raid_dp,
                                                                       mirror
                                                                       degraded
    node_A_2_data02_unmirrored
                2.18TB    2.18TB    0% online       1 node_A_2       raid_dp,
                                                                       normal
    node_A_2_root
               707.7GB   34.27GB   95% online       1 node_A_2       raid_dp,
                                                                       mirror
                                                                       degraded
    cluster_A::> storage aggregate show -r -node node_A_2 !*root
    Owner Node: node_A_2
     Aggregate: node_A_2_data01_mirrored (online, raid_dp, mirror degraded) (block checksums)
      Plex: /node_A_2_data01_mirrored/plex0 (online, normal, active, pool0)
       RAID Group /node_A_2_data01_mirrored/plex0/rg0 (normal, block checksums)
                                                                  Usable Physical
         Position Disk                        Pool Type     RPM     Size     Size Status
         -------- --------------------------- ---- ----- ------ -------- -------- ----------
         dparity  2.30.3                       0   BSAS    7200  827.7GB  828.0GB (normal)
         parity   2.30.4                       0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.6                       0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.8                       0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.5                       0   BSAS    7200  827.7GB  828.0GB (normal)
    
      Plex: /node_A_2_data01_mirrored/plex4 (offline, failed, inactive, pool1)
       RAID Group /node_A_2_data01_mirrored/plex4/rg0 (partial, none checksums)
                                                                  Usable Physical
         Position Disk                        Pool Type     RPM     Size     Size Status
         -------- --------------------------- ---- ----- ------ -------- -------- ----------
         dparity  FAILED                       -   -          -  827.7GB        - (failed)
         parity   FAILED                       -   -          -  827.7GB        - (failed)
         data     FAILED                       -   -          -  827.7GB        - (failed)
         data     FAILED                       -   -          -  827.7GB        - (failed)
         data     FAILED                       -   -          -  827.7GB        - (failed)
    
     Aggregate: node_A_2_data02_unmirrored (online, raid_dp) (block checksums)
      Plex: /node_A_2_data02_unmirrored/plex0 (online, normal, active, pool0)
       RAID Group /node_A_2_data02_unmirrored/plex0/rg0 (normal, block checksums)
                                                                  Usable Physical
         Position Disk                        Pool Type     RPM     Size     Size Status
         -------- --------------------------- ---- ----- ------ -------- -------- ----------
         dparity  2.30.12                      0   BSAS    7200  827.7GB  828.0GB (normal)
         parity   2.30.22                      0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.21                      0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.20                      0   BSAS    7200  827.7GB  828.0GB (normal)
         data     2.30.14                      0   BSAS    7200  827.7GB  828.0GB (normal)
    15 entries were displayed.
  7. Verify that the data is being served and that all volumes are still online:

    vserver show -type data

    network interface show -fields is-home false

    volume show !vol0,!MDV*

    cluster_A::> vserver show -type data
    
    cluster_A::> vserver show -type data
                                   Admin      Operational Root
    Vserver     Type    Subtype    State      State       Volume     Aggregate
    ----------- ------- ---------- ---------- ----------- ---------- ----------
    SVM1        data    sync-source           running     SVM1_root  node_A_1_data01_mirrored
    SVM2        data    sync-source	          running     SVM2_root  node_A_1_data01_mirrored
    
    cluster_A::> network interface show -fields is-home false
    There are no entries matching your query.
    
    cluster_A::> volume show !vol0,!MDV*
    Vserver   Volume       Aggregate    State      Type       Size  Available Used%
    --------- ------------ ------------ ---------- ---- ---------- ---------- -----
    SVM1
              SVM1_root
                           node_A_1data01_mirrored
                                        online     RW         10GB     9.50GB    5%
    SVM1
              SVM1_data_vol
                           node_A_1data01_mirrored
                                        online     RW         10GB     9.49GB    5%
    SVM2
              SVM2_root
                           node_A_1data01_mirrored
                                        online     RW         10GB     9.49GB    5%
    SVM2
              SVM2_data_vol
                           node_A_2_data02_unmirrored
                                        online     RW          1GB    972.6MB    5%
  8. Physically power on the shelf.

    Resynchronization starts automatically.

  9. Verify that resynchronization has started:

    storage aggregate show

    The affected aggregate should have a “resyncing” RAID status, as shown in the following example:

    cluster_A::> storage aggregate show
    cluster Aggregates:
    Aggregate     Size Available Used% State   #Vols  Nodes            RAID Status
    --------- -------- --------- ----- ------- ------ ---------------- ------------
    node_A_1_data01_mirrored
                4.15TB    3.40TB   18% online       3 node_A_1       raid_dp,
                                                                       mirrored,
                                                                       normal
    node_A_1_root
               707.7GB   34.29GB   95% online       1 node_A_1       raid_dp,
                                                                       mirrored,
                                                                       normal
    node_A_2_data01_mirrored
                4.15TB    4.12TB    1% online       2 node_A_2       raid_dp,
                                                                       resyncing
    node_A_2_data02_unmirrored
                2.18TB    2.18TB    0% online       1 node_A_2       raid_dp,
                                                                       normal
    node_A_2_root
               707.7GB   34.27GB   95% online       1 node_A_2       raid_dp,
                                                                       resyncing
  10. Monitor the aggregate to confirm that resynchronization is complete:

    storage aggregate show

    The affected aggregate should have a “normal” RAID status, as shown in the following example:

    cluster_A::> storage aggregate show
    cluster Aggregates:
    Aggregate     Size Available Used% State   #Vols  Nodes            RAID Status
    --------- -------- --------- ----- ------- ------ ---------------- ------------
    node_A_1data01_mirrored
                4.15TB    3.40TB   18% online       3 node_A_1       raid_dp,
                                                                       mirrored,
                                                                       normal
    node_A_1root
               707.7GB   34.29GB   95% online       1 node_A_1       raid_dp,
                                                                       mirrored,
                                                                       normal
    node_A_2_data01_mirrored
                4.15TB    4.12TB    1% online       2 node_A_2       raid_dp,
                                                                       normal
    node_A_2_data02_unmirrored
                2.18TB    2.18TB    0% online       1 node_A_2       raid_dp,
                                                                       normal
    node_A_2_root
               707.7GB   34.27GB   95% online       1 node_A_2       raid_dp,
                                                                       resyncing