Renaming a Brocade FC switch
You might need to rename a Brocade FC switch to ensure consistent naming throughout your configuration.
Enable console logging before performing this task.
-
Persistently disable the switch or switches in one fabric:
switchcfgpersistentdisable
The following example shows the output for the
switchcfgpersistentdisable
command:7840_FCIP_2:admin> switchcfgpersistentdisable Switch's persistent state set to 'disabled' 2018/03/09-07:41:06, [ESM-2105], 146080, FID 128, INFO, 7840_FCIP_2, VE Tunnel 24 is DEGRADED. 2018/03/09-07:41:06, [ESM-2104], 146081, FID 128, INFO, 7840_FCIP_2, VE Tunnel 24 is OFFLINE. 7840_FCIP_2:admin>
-
Rename the switch or switches:
switchname new-switch-name
If you are renaming both switches in the fabric, use the same command on each switch.
The following example shows the output for the
switchname new-switch-name
command:7840_FCIP_2:admin> switchname FC_switch_1_B Committing configuration... Done. Switch name has been changed.Please re-login into the switch for the change to be applied. 2018/03/09-07:41:20, [IPAD-1002], 146082, FID 128, INFO, FC_switch_1_B, Switch name has been successfully changed to FC_switch_1_B. 7840_FCIP_2:admin>
-
Reboot the switch or switches:
reboot
If you are renaming both switches in the fabric, reboot both switches. Once the reboot is complete, the switch is renamed in all places.
The following example shows the output for the
reboot
command:7840_FCIP_2:admin> reboot Warning: This command would cause the switch to reboot and result in traffic disruption. Are you sure you want to reboot the switch [y/n]?y 2018/03/09-07:42:08, [RAS-1007], 146083, CHASSIS, INFO, Brocade7840, System is about to reload. Rebooting! Fri Mar 9 07:42:11 CET 2018 Broadcast message from root (ttyS0) Fri Mar 9 07:42:11 2018... The system is going down for reboot NOW !! INIT: Switching to runlevel: 6 INIT: 2018/03/09-07:50:48, [ESM-1013], 146104, FID 128, INFO, FC_switch_1_B, DP0 Configuration replay has completed. 2018/03/09-07:50:48, [ESM-1011], 146105, FID 128, INFO, FC_switch_1_B, DP0 is ONLINE. *** CORE FILES WARNING (03/09/18 - 08:00:00 ) *** 10248 KBytes in 1 file(s) use "supportsave" command to upload *** FFDC FILES WARNING (03/09/18 - 08:00:00 ) *** 520 KBytes in 1 file(s)
-
Persistently enable the switches:
switchcfgpersistentenable
The following example shows the output for the
switchcfgpersistentenable
command:FC_switch_1_B:admin> switchcfgpersistentenable Switch's persistent state set to 'enabled' FC_switch_1_B:admin> FC_switch_1_B:admin> FC_switch_1_B:admin> 2018/03/09-08:07:07, [ESM-2105], 146106, FID 128, INFO, FC_switch_1_B, VE Tunnel 24 is DEGRADED. 2018/03/09-08:07:10, [ESM-2106], 146107, FID 128, INFO, FC_switch_1_B, VE Tunnel 24 is ONLINE. FC_switch_1_B:admin> FC_switch_1_B:admin> switchshow switchName: FC_switch_1_B switchType: 148.0 switchState: Online switchMode: Native switchRole: Subordinate switchDomain: 6 switchId: fffc06 switchWwn: 10:00:50:eb:1a:9a:a5:79 zoning: ON (CFG_FAB_2_RCF_9_3) switchBeacon: OFF FC Router: OFF FC Router BB Fabric ID: 128 Address Mode: 0 HIF Mode: OFF Index Port Address Media Speed State Proto ================================================== 0 0 060000 id 16G Online FC F-Port 50:0a:09:81:06:a5:5a:08 1 1 060100 id 16G Online FC F-Port 50:0a:09:83:06:a5:5a:08
-
Verify that the switch name change is visible from the ONTAP cluster prompt:
storage switch show
The following example shows the output for the
storage switch show
command:cluster_A::*> storage switch show (storage switch show) Symbolic Is Monitor Switch Name Vendor Model Switch WWN Monitored Status --------------------- -------- ------- ----- ---------------- --------- ------- Brocade_172.20.7.90 RTP-FC01-510Q40 Brocade Brocade7840 1000c4f57c904bc8 true ok Brocade_172.20.7.91 RTP-FC02-510Q40 Brocade Brocade7840 100050eb1a9aa579 true ok Brocade_172.20.7.92