Create an NVMe subsystem
Creates an NVMe subsystem to define the structure for NVMe resources within an existing SVM. This operation is used to establish the subsystem's configuration, including its name and operating system type for host compatibility.
HTTP method and endpoint
POST /protocols/nvme/subsystems
Introduced in
ONTAP 9.6
Required properties
-
svm.uuidorsvm.name- Existing SVM in which to create the NVMe subsystem. -
name- Name for NVMe subsystem. Once created, an NVMe subsytem cannot be renamed. -
os_type- Operating system of the NVMe subsystem's hosts.
Related ONTAP commands
-
vserver nvme subsystem create
Learn more
Parameters
| Name | Type | In | Required | Description |
|---|---|---|---|---|
return_records |
boolean |
query |
False |
The default is false. If set to true, the records are returned.
|
Request Body
| Name | Type | Description |
|---|---|---|
comment |
string |
A configurable comment for the NVMe subsystem. Optional in POST and PATCH. |
delete_on_unmap |
boolean |
An option that causes the subsystem to be deleted when the last subsystem map associated with it is deleted. This property defaults to false when the subsystem is created. |
hosts |
array[hosts] |
The NVMe hosts configured for access to the NVMe subsystem. Optional in POST. |
io_queue |
The properties of the submission queue used to submit I/O commands for execution by the NVMe controller. |
|
name |
string |
The name of the NVMe subsystem. Once created, an NVMe subsystem cannot be renamed. Required in POST. |
os_type |
string |
The host operating system of the NVMe subsystem's hosts. Required in POST. |
serial_number |
string |
The serial number of the NVMe subsystem. |
subsystem_maps |
array[subsystem_maps] |
The NVMe namespaces mapped to the NVMe subsystem. There is an added cost to retrieving property values for |
svm |
||
target_nqn |
string |
The NVMe qualified name (NQN) used to identify the NVMe storage target. |
uuid |
string |
The unique identifier of the NVMe subsystem. |
vendor_uuids |
array[string] |
Vendor-specific identifiers (UUIDs) optionally assigned to an NVMe subsystem when the subsystem is created. The identifiers are used to enable vendor-specific NVMe protocol features. The identifiers are provided by a host application vendor and shared with NetApp prior to a joint product release. Creating an NVMe subsystem with an unknown or non-specific identifier will have no effect on the NVMe subsystem. Refer to the ONTAP SAN Administration Guide for a list of the supported vendor-specific identifiers. After a subsystem is created, the vendor-specific identifiers cannot be changed or removed. Optional in POST.
|
Example request
{
"comment": "string",
"hosts": [
{
"nqn": "nqn.1992-01.example.com:string"
}
],
"io_queue": {
"default": {
"count": 4,
"depth": 16
}
},
"name": "subsystem1",
"os_type": "string",
"serial_number": "wCVsgFMiuMhVAAAAAAAB",
"subsystem_maps": [
{
"anagrpid": "00103050h",
"namespace": {
"name": "/vol/vol1/namespace1",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412"
},
"nsid": "00000001h"
}
],
"svm": {
"name": "svm1",
"uuid": "02c9e252-41be-11e9-81d5-00a0986138f7"
},
"target_nqn": "nqn.1992-01.example.com:string",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412",
"vendor_uuids": [
"1447f0f4-42e5-0dfc-871a-dc9b3f92d8f8"
]
}
Response
Status: 201, Created
| Name | Type | Description |
|---|---|---|
num_records |
integer |
Number of records. |
records |
array[nvme_subsystem] |
Example response
{
"records": [
{
"comment": "string",
"hosts": [
{
"nqn": "nqn.1992-01.example.com:string"
}
],
"io_queue": {
"default": {
"count": 4,
"depth": 16
}
},
"name": "subsystem1",
"os_type": "string",
"serial_number": "wCVsgFMiuMhVAAAAAAAB",
"subsystem_maps": [
{
"anagrpid": "00103050h",
"namespace": {
"name": "/vol/vol1/namespace1",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412"
},
"nsid": "00000001h"
}
],
"svm": {
"name": "svm1",
"uuid": "02c9e252-41be-11e9-81d5-00a0986138f7"
},
"target_nqn": "nqn.1992-01.example.com:string",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412",
"vendor_uuids": [
"1447f0f4-42e5-0dfc-871a-dc9b3f92d8f8"
]
}
]
}
Error
Status: Default
ONTAP Error Response Codes
| Error Code | Description |
|---|---|
2621462 |
The supplied SVM does not exist. |
2621706 |
The specified |
2621707 |
The svm.uuid or svm.name must be provided. |
72089635 |
Setting vendor-specific UUIDs on NVMe subsystems is not supported until the effective cluster version is 9.9 or later. |
72089709 |
The NVMe subsystem name contains an invalid character. |
72089711 |
An invalid vendor-specific UUID was specified. |
72089712 |
A duplicate vendor-specific UUID was specific. |
72089713 |
Too many vendor UUIDs were supplied. |
72089771 |
The NQN is invalid. A non-empty qualifier is required after the prefix. An example of a valid NQN is nqn.1992-01.com.example:string. |
72089772 |
The NQN is invalid. Add the prefix 'nqn'. An example of a valid NQN is nqn.1992-01.com.example:string. |
72089773 |
The NQN is invalid. The date field must be formatted yyyy-mm. An example of a valid NQN is nqn.1992-01.com.example:string. |
72090025 |
The NVMe subsystem already exists for the SVM. |
72090029 |
The NVMe service does not exist. |
72090030 |
A partial success occured while adding multiple NVMe subsystem hosts to an NVMe subsystem. |
72090035 |
Passing NVMe subsystem host NQNs on NVMe subsystem POST requires an effective cluster version of 9.7 or later. |
72090036 |
The |
Definitions
See Definitions
href
| Name | Type | Description |
|---|---|---|
href |
string |
_links
hosts
| Name | Type | Description |
|---|---|---|
nqn |
string |
The NVMe qualified name (NQN) used to identify the NVMe storage target. |
default
The default I/O queue parameters inherited by NVMe hosts in the NVMe subsystem.
| Name | Type | Description |
|---|---|---|
count |
integer |
The number of host I/O queue pairs. |
depth |
integer |
The host I/O queue depth. |
io_queue
The properties of the submission queue used to submit I/O commands for execution by the NVMe controller.
| Name | Type | Description |
|---|---|---|
default |
The default I/O queue parameters inherited by NVMe hosts in the NVMe subsystem. |
namespace
An NVMe namespace mapped to the NVMe subsystem.
| Name | Type | Description |
|---|---|---|
name |
string |
The name of the NVMe namespace. |
uuid |
string |
The unique identifier of the NVMe namespace. |
subsystem_maps
An NVMe namespace mapped to the NVMe subsystem.
| Name | Type | Description |
|---|---|---|
anagrpid |
string |
The Asymmetric Namespace Access Group ID (ANAGRPID) of the NVMe namespace. The format for an ANAGRPIP is 8 hexadecimal digits (zero-filled) followed by a lower case "h". |
namespace |
An NVMe namespace mapped to the NVMe subsystem. |
|
nsid |
string |
The NVMe namespace identifier. This is an identifier used by an NVMe controller to provide access to the NVMe namespace. The format for an NVMe namespace identifier is 8 hexadecimal digits (zero-filled) followed by a lower case "h". |
svm
| Name | Type | Description |
|---|---|---|
name |
string |
The name of the SVM. |
uuid |
string |
The unique identifier of the SVM. |
nvme_subsystem
An NVMe subsystem maintains configuration state and namespace access control for a set of NVMe-connected hosts.
| Name | Type | Description |
|---|---|---|
comment |
string |
A configurable comment for the NVMe subsystem. Optional in POST and PATCH. |
delete_on_unmap |
boolean |
An option that causes the subsystem to be deleted when the last subsystem map associated with it is deleted. This property defaults to false when the subsystem is created. |
hosts |
array[hosts] |
The NVMe hosts configured for access to the NVMe subsystem. Optional in POST. |
io_queue |
The properties of the submission queue used to submit I/O commands for execution by the NVMe controller. |
|
name |
string |
The name of the NVMe subsystem. Once created, an NVMe subsystem cannot be renamed. Required in POST. |
os_type |
string |
The host operating system of the NVMe subsystem's hosts. Required in POST. |
serial_number |
string |
The serial number of the NVMe subsystem. |
subsystem_maps |
array[subsystem_maps] |
The NVMe namespaces mapped to the NVMe subsystem. There is an added cost to retrieving property values for |
svm |
||
target_nqn |
string |
The NVMe qualified name (NQN) used to identify the NVMe storage target. |
uuid |
string |
The unique identifier of the NVMe subsystem. |
vendor_uuids |
array[string] |
Vendor-specific identifiers (UUIDs) optionally assigned to an NVMe subsystem when the subsystem is created. The identifiers are used to enable vendor-specific NVMe protocol features. The identifiers are provided by a host application vendor and shared with NetApp prior to a joint product release. Creating an NVMe subsystem with an unknown or non-specific identifier will have no effect on the NVMe subsystem. Refer to the ONTAP SAN Administration Guide for a list of the supported vendor-specific identifiers. After a subsystem is created, the vendor-specific identifiers cannot be changed or removed. Optional in POST.
|
error_arguments
| Name | Type | Description |
|---|---|---|
code |
string |
Argument code |
message |
string |
Message argument |
error
| Name | Type | Description |
|---|---|---|
arguments |
array[error_arguments] |
Message arguments |
code |
string |
Error code |
message |
string |
Error message |
target |
string |
The target parameter that caused the error. |