Retrieve NVMe subsystems
GET /protocols/nvme/subsystems
Introduced In: 9.6
Retrieves NVMe subsystems.
Related ONTAP commands
-
vserver nvme subsystem host show
-
vserver nvme subsystem map show
-
vserver nvme subsystem show
Learn more
Parameters
Name | Type | In | Required | Description |
---|---|---|---|---|
comment |
string |
query |
False |
Filter by comment
|
serial_number |
string |
query |
False |
Filter by serial_number
|
target_nqn |
string |
query |
False |
Filter by target_nqn
|
svm.uuid |
string |
query |
False |
Filter by svm.uuid |
svm.name |
string |
query |
False |
Filter by svm.name |
io_queue.default.depth |
integer |
query |
False |
Filter by io_queue.default.depth
|
io_queue.default.count |
integer |
query |
False |
Filter by io_queue.default.count
|
name |
string |
query |
False |
Filter by name
|
hosts.nqn |
string |
query |
False |
Filter by hosts.nqn |
hosts.dh_hmac_chap.mode |
string |
query |
False |
Filter by hosts.dh_hmac_chap.mode
|
hosts.dh_hmac_chap.group_size |
string |
query |
False |
Filter by hosts.dh_hmac_chap.group_size
|
hosts.dh_hmac_chap.hash_function |
string |
query |
False |
Filter by hosts.dh_hmac_chap.hash_function
|
os_type |
string |
query |
False |
Filter by os_type |
delete_on_unmap |
boolean |
query |
False |
Filter by delete_on_unmap
|
subsystem_maps.nsid |
string |
query |
False |
Filter by subsystem_maps.nsid |
subsystem_maps.anagrpid |
string |
query |
False |
Filter by subsystem_maps.anagrpid |
subsystem_maps.namespace.uuid |
string |
query |
False |
Filter by subsystem_maps.namespace.uuid |
subsystem_maps.namespace.name |
string |
query |
False |
Filter by subsystem_maps.namespace.name |
uuid |
string |
query |
False |
Filter by uuid |
vendor_uuids |
string |
query |
False |
Filter by vendor_uuids
|
fields |
array[string] |
query |
False |
Specify the fields to return. |
max_records |
integer |
query |
False |
Limit the number of records returned. |
return_records |
boolean |
query |
False |
The default is true for GET calls. When set to false, only the number of records is returned.
|
return_timeout |
integer |
query |
False |
The number of seconds to allow the call to execute before returning. When iterating over a collection, the default is 15 seconds. ONTAP returns earlier if either max records or the end of the collection is reached.
|
order_by |
array[string] |
query |
False |
Order results by specified fields and optional [asc |
Response
Status: 200, Ok
Name | Type | Description |
---|---|---|
_links |
||
num_records |
integer |
The number of records in the response. |
records |
array[nvme_subsystem] |
Example response
{
"_links": {
"next": {
"href": "/api/resourcelink"
},
"self": {
"href": "/api/resourcelink"
}
},
"num_records": 1,
"records": [
{
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"comment": "string",
"hosts": [
{
"dh_hmac_chap": {
"controller_secret_key": "DHHC-1:00:ia6zGodOr4SEG0Zzaw398rpY0wqipUWj4jWjUh4HWUz6aQ2n:",
"group_size": "string",
"hash_function": "string",
"host_secret_key": "DHHC-1:00:ia6zGodOr4SEG0Zzaw398rpY0wqipUWj4jWjUh4HWUz6aQ2n:",
"mode": "bidirectional"
},
"nqn": "nqn.1992-01.example.com:string"
}
],
"io_queue": {
"default": {
"count": 4,
"depth": 16
}
},
"name": "subsystem1",
"os_type": "string",
"serial_number": "wCVsgFMiuMhVAAAAAAAB",
"subsystem_maps": [
{
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"anagrpid": "00103050h",
"namespace": {
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"name": "/vol/vol1/namespace1",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412"
},
"nsid": "00000001h"
}
],
"svm": {
"_links": {
"self": {
"href": "/api/resourcelink"
}
},
"name": "svm1",
"uuid": "02c9e252-41be-11e9-81d5-00a0986138f7"
},
"target_nqn": "nqn.1992-01.example.com:string",
"uuid": "1cd8a442-86d1-11e0-ae1c-123478563412",
"vendor_uuids": [
"1447f0f4-42e5-0dfc-871a-dc9b3f92d8f8"
]
}
]
}
Error
Status: Default, Error
Name | Type | Description |
---|---|---|
error |
Example error
{
"error": {
"arguments": [
{
"code": "string",
"message": "string"
}
],
"code": "4",
"message": "entry doesn't exist",
"target": "uuid"
}
}
Definitions
See Definitions
href
Name | Type | Description |
---|---|---|
href |
string |
_links
Name | Type | Description |
---|---|---|
next |
||
self |
_links
Name | Type | Description |
---|---|---|
self |
dh_hmac_chap
A container for properties of NVMe in-band authentication with the DH-HMAC-CHAP protocol.
Name | Type | Description |
---|---|---|
controller_secret_key |
string |
The controller secret for NVMe in-band authentication. The value of this property is used by the NVMe host to authenticate the NVMe controller while establishing a connection. If unset, the controller is not authenticated. When supplied, the property This property is write-only. The |
group_size |
string |
The Diffie-Hellman group size for NVMe in-band authentication. When property |
hash_function |
string |
The hash function for NVMe in-band authentication. When property |
host_secret_key |
string |
The host secret for NVMe in-band authentication. The value of this property is used by the NVMe controller to authenticate the NVMe host while establishing a connection. If unset, no authentication is performed by the host or controller. This property must be supplied if any other NVMe in-band authentication properties are supplied. Optional in POST. This property is write-only. The |
mode |
string |
The expected NVMe in-band authentication mode for the host. This property is an indication of which secrets are configured for the host. When set to:
|
hosts
Name | Type | Description |
---|---|---|
dh_hmac_chap |
A container for properties of NVMe in-band authentication with the DH-HMAC-CHAP protocol. |
|
nqn |
string |
The NVMe qualified name (NQN) used to identify the NVMe storage target. |
default
The default I/O queue parameters inherited by NVMe hosts in the NVMe subsystem.
Name | Type | Description |
---|---|---|
count |
integer |
The number of host I/O queue pairs. |
depth |
integer |
The host I/O queue depth. |
io_queue
The properties of the submission queue used to submit I/O commands for execution by the NVMe controller.
Name | Type | Description |
---|---|---|
default |
The default I/O queue parameters inherited by NVMe hosts in the NVMe subsystem. |
namespace
An NVMe namespace mapped to the NVMe subsystem.
Name | Type | Description |
---|---|---|
_links |
||
name |
string |
The name of the NVMe namespace. |
uuid |
string |
The unique identifier of the NVMe namespace. |
subsystem_maps
An NVMe namespace mapped to the NVMe subsystem.
Name | Type | Description |
---|---|---|
_links |
||
anagrpid |
string |
The Asymmetric Namespace Access Group ID (ANAGRPID) of the NVMe namespace. The format for an ANAGRPIP is 8 hexadecimal digits (zero-filled) followed by a lower case "h". |
namespace |
An NVMe namespace mapped to the NVMe subsystem. |
|
nsid |
string |
The NVMe namespace identifier. This is an identifier used by an NVMe controller to provide access to the NVMe namespace. The format for an NVMe namespace identifier is 8 hexadecimal digits (zero-filled) followed by a lower case "h". |
svm
Name | Type | Description |
---|---|---|
_links |
||
name |
string |
The name of the SVM. |
uuid |
string |
The unique identifier of the SVM. |
nvme_subsystem
An NVMe subsystem maintains configuration state and namespace access control for a set of NVMe-connected hosts.
Name | Type | Description |
---|---|---|
_links |
||
comment |
string |
A configurable comment for the NVMe subsystem. Optional in POST and PATCH. |
delete_on_unmap |
boolean |
An option that causes the subsystem to be deleted when the last subsystem map associated with it is deleted. Optional in POST and PATCH. This property defaults to false when the subsystem is created. |
hosts |
array[hosts] |
The NVMe hosts configured for access to the NVMe subsystem. Optional in POST. |
io_queue |
The properties of the submission queue used to submit I/O commands for execution by the NVMe controller. |
|
name |
string |
The name of the NVMe subsystem. Once created, an NVMe subsystem cannot be renamed. Required in POST. |
os_type |
string |
The host operating system of the NVMe subsystem's hosts. Required in POST. |
serial_number |
string |
The serial number of the NVMe subsystem. |
subsystem_maps |
array[subsystem_maps] |
The NVMe namespaces mapped to the NVMe subsystem. There is an added computational cost to retrieving property values for |
svm |
||
target_nqn |
string |
The NVMe qualified name (NQN) used to identify the NVMe storage target. |
uuid |
string |
The unique identifier of the NVMe subsystem. |
vendor_uuids |
array[string] |
Vendor-specific identifiers (UUIDs) optionally assigned to an NVMe subsystem when the subsystem is created. The identifiers are used to enable vendor-specific NVMe protocol features. The identifiers are provided by a host application vendor and shared with NetApp prior to a joint product release. Creating an NVMe subsystem with an unknown or non-specific identifier will have no effect on the NVMe subsystem. Refer to the ONTAP SAN Administration Guide for a list of the supported vendor-specific identifiers. After a subsystem is created, the vendor-specific identifiers cannot be changed or removed. Optional in POST.
|
error_arguments
Name | Type | Description |
---|---|---|
code |
string |
Argument code |
message |
string |
Message argument |
error
Name | Type | Description |
---|---|---|
arguments |
array[error_arguments] |
Message arguments |
code |
string |
Error code |
message |
string |
Error message |
target |
string |
The target parameter that caused the error. |