A newer release of this product is available.
Manage cluster firmware history
Retrieve a detailed history of firmware update requests on your cluster using this API. Use these endpoints to gain insights into past firmware activities, ensuring you're informed about successful updates and any issues encountered.
Overview
Use this API to retrieve a history of firmware update requests. This API supports GET calls.
Examples
Retrieving history of firmware updates
The following example retrieves a history of firmware updates performed on the cluster. Note that if the fields=* parameter is not specified, only the job ID and start time are returned. Filters can be added on the fields to limit the results.
# The API:
GET /api/cluster/firmware/history
# The call:
curl -X GET "https://<mgmt-ip>/api/cluster/firmware/history/?fields=*" -H "accept: application/hal+json"
# The response:
200 OK
{
"records": [
{
"start_time": "1970-01-01T00:02:03+00:00",
"job": {
"uuid": "adf700c2-b50e-11ea-a54f-005056bbec43"
},
"node": {
"uuid": "0530d6c1-8c6d-11e8-907f-00a0985a72ee",
"name": "node1"
},
"fw_file_name": "all_disk_fw.zip",
"fw_update_state": "starting_workers",
"end_time": "1970-01-01T00:07:36+00:00",
"update_status": [
{
"worker": {
"node": {
"uuid": "0530d6c1-8c6d-11e8-907f-00a0985a72ee",
"name": "node1"
},
"state": "failed",
"error": {
"message": "A firmware file already exists.",
"code": 2228327
}
}
},
{
"worker": {
"node": {
"uuid": "0530d6c1-8c6d-11e8-907f-00a0985a72ef",
"name": "node2"
},
"state": "complete",
"error": {
"message": "Success",
"code": 0
}
}
}
],
"_links": {
"self": {
"href": "/api/cluster/firmware/history/1970-01-01T00%3A02%3A03-00%3A00/adf700c2-b50e-11ea-a54f-005056bbec43"
}
}
},
{
"start_time": "1970-01-01T00:02:03+00:00",
"job": {
"uuid": "f84adabe-b50e-11ea-a54f-005056bbec43"
},
"node": {
"uuid": "0530d6c1-8c6d-11e8-907f-00a0985a72ee",
"name": "node1"
},
"fw_file_name": "all_shelf_fw.zip",
"fw_update_state": "completed",
"end_time": "1970-01-01T00:07:36+00:00",
"update_status": [
{
"worker": {
"node": {
"uuid": "0530d6c1-8c6d-11e8-907f-00a0985a72ee",
"name": "node1"
},
"state": "failed",
"error": {
"message": "A firmware file already exists.",
"code": 2228327
}
}
},
{
"worker": {
"node": {
"uuid": "0530d6c1-8c6d-11e8-907f-00a0985a72ef",
"name": "node2"
},
"state": "complete",
"error": {
"message": "Success",
"code": 0
}
}
}
],
"_links": {
"self": {
"href": "/api/cluster/firmware/history/1970-01-01T00%3A02%3A03-00%3A00/f84adabe-b50e-11ea-a54f-005056bbec43"
}
}
}
],
"num_records": 2,
"_links": {
"self": {
"href": "/api/cluster/firmware/history/?fields=%2A"
}
}
}