Configure RHEL 8.8 for NVMe-oF with ONTAP storage
Red Hat Enterpirse Linux (RHEL) hosts support the NVMe over Fibre Channel (NVMe/FC) and NVMe over TCP (NVMe/TCP) protocols with Asymmetric Namespace Access (ANA). ANA provides multipathing functionality equivalent to asymmetric logical unit access (ALUA) in iSCSI and FCP environments.
Learn how to configure NVMe over Fabrics (NVMe-oF) hosts for RHEL 8.8. For more support and feature information, see NVME-oF Overview.
NVMe-oF with RHEL 8.8 has the following known limitations:
-
SAN booting using the NVMe-oF protocol is not currently supported.
-
In-kernel NVMe multipath is disabled by default on NVMe-oF hosts in RHEL 8.8; you must enable it manually.
-
NVMe/TCP is available as a technology preview due to known issues.
Step 1: Optionally, enable SAN booting
You can configure your host to use SAN booting to simplify deployment and improve scalability. Use the Interoperability Matrix Tool to verify that your Linux OS, host bus adapter (HBA), HBA firmware, HBA boot BIOS, and ONTAP version support SAN booting.
-
Enable SAN booting in the server BIOS for the ports to which the SAN boot namespace is mapped.
For information on how to enable the HBA BIOS, see your vendor-specific documentation.
-
Reboot the host and verify that the OS is up and running.
Step 2: Verify the software version and NVMe configuration
Check that your system meets software requirements and verify NVMe package installations and host configuration.
-
Install RHEL 8.8 on the server. After the installation is complete, verify that you are running the required RHEL 8.8 kernel:
uname -r
Example RHEL kernel version:
4.18.0-477.10.1.el8_8.x86_64
-
Install the
nvme-cli
package:rpm -qa|grep nvme-cli
The following example shows an nvme-cli package version:
nvme-cli-1.16-7.el8.x86_64
-
Install the
libnvme
package:rpm -qa|grep libnvme
The following example shows an libnvme package version:
libnvme-1.4-3.el8.x86_64
-
Enable in-kernel NVMe multipath:
grubby --args=nvme_core.multipath=Y --update-kernel /boot/vmlinuz-4.18.0-477.10.1.el8_8.x86_64
-
On the RHEL 8.8 host, check the
hostnqn
string at/etc/nvme/hostnqn
:cat /etc/nvme/hostnqn
The following example shows an
hostnqn
version:nqn.2014-08.org.nvmexpress:uuid:f6517cae-3133-11e8-bbff-7ed30aef123f
-
Verify that the
hostnqn
string matches thehostnqn
string for the corresponding subsystem on the ONTAP storage system:::> vserver nvme subsystem host show -vserver vs_fcnvme_141
Show example
Vserver Subsystem Host NQN ----------- --------------- ---------------------------------------------------------- vs_nvme161 rhel_161_LPe32002 nqn.2014-08.org.nvmexpress:uuid:f6517cae-3133-11e8-bbff-7ed30aef123f
If the hostnqn
strings do not match, use thevserver modify
command to update thehostnqn
string on your corresponding ONTAP storage system subsystem to match thehostnqn
string from/etc/nvme/hostnqn
on the host. -
Reboot the host.
To run both NVMe and SCSI traffic on the same host, NetApp recommends using the in-kernel NVMe multipath for ONTAP namespaces and dm-multipath for ONTAP LUNs. To prevent dm-multipath from claiming ONTAP namespace devices, exclude them by adding the
enable_foreign
setting to the/etc/multipath.conf
file:cat /etc/multipath.conf defaults { enable_foreign NONE }
Step 3: Configure NVMe/FC and NVMe/TCP
Configure NVMe/FC with Broadcom/Emulex or Marvell/QLogic adapters, or configure NVMe/TCP using manual discovery and connect operations.
Configure NVMe/FC for a Broadcom/Emulex adapter.
-
Verify that you are using the supported adapter model:
-
Display the model names:
cat /sys/class/scsi_host/host*/modelname
You should see output similar to the following example:
LPe32002-M2 LPe32002-M2
-
Display the model descriptions:
cat /sys/class/scsi_host/host*/modeldesc
You should see output similar to the following example:
Emulex LightPulse LPe32002-M2 2-Port 32Gb Fibre Channel Adapter Emulex LightPulse LPe32002-M2 2-Port 32Gb Fibre Channel Adapter
-
-
Verify that you are using the recommended Broadcom
lpfc
firmware and inbox driver:-
Display the firmware version:
cat /sys/class/scsi_host/host*/fwrev
The command returns the firmware versions:
14.0.639.18, sli-4:2:c 14.0.639.18, sli-4:2:c
-
Display the inbox driver version:
cat /sys/module/lpfc/version
The following example shows a driver version:
0:14.0.0.18
For the current list of supported adapter driver and firmware versions, see the Interoperability Matrix Tool.
-
-
Verify that
lpfc_enable_fc4_type
is set to3
:cat /sys/module/lpfc/parameters/lpfc_enable_fc4_type
-
Verify that you can view your initiator ports:
cat /sys/class/fc_host/host*/port_name
You should see output similar to the following example:
0x100000109b1c1204 0x100000109b1c1205
-
Verify that your initiator ports are online:
cat /sys/class/fc_host/host*/port_state
You should see the following output:
Online Online
-
Verify that the NVMe/FC initiator ports are enabled and that the target ports are visible:
cat /sys/class/scsi_host/host*/nvme_info
Show example
NVME Initiator Enabled XRI Dist lpfc0 Total 6144 IO 5894 ELS 250 NVME LPORT lpfc0 WWPN x10000090fae0ec88 WWNN x20000090fae0ec88 DID x0a1300 ONLINE NVME RPORT WWPN x2049d039ea36a105 WWNN x2048d039ea36a105 DID x0a0c0a TARGET DISCSRVC ONLINE NVME RPORT WWPN x204bd039ea36a105 WWNN x2048d039ea36a105 DID x0a100a TARGET DISCSRVC ONLINE NVME Statistics LS: Xmt 0000000134 Cmpl 0000000134 Abort 00000000 LS XMIT: Err 00000000 CMPL: xb 00000000 Err 00000000 Total FCP Cmpl 000000000825e567 Issue 000000000825d7ed OutIO fffffffffffff286 abort 0000027c noxri 00000000 nondlp 00000a02 qdepth 00000000 wqerr 00000000 err 00000000 FCP CMPL: xb 00000782 Err 000130fa NVME Initiator Enabled XRI Dist lpfc1 Total 6144 IO 5894 ELS 250 NVME LPORT lpfc1 WWPN x10000090fae0ec89 WWNN x20000090fae0ec89 DID x0a1200 ONLINE NVME RPORT WWPN x204ad039ea36a105 WWNN x2048d039ea36a105 DID x0a080a TARGET DISCSRVC ONLINE NVME RPORT WWPN x204cd039ea36a105 WWNN x2048d039ea36a105 DID x0a090a TARGET DISCSRVC ONLINE NVME Statistics LS: Xmt 0000000134 Cmpl 0000000134 Abort 00000000 LS XMIT: Err 00000000 CMPL: xb 00000000 Err 00000000 Total FCP Cmpl 000000000826ced5 Issue 000000000826c226 OutIO fffffffffffff351 abort 0000029d noxri 00000000 nondlp 000008df qdepth 00000000 wqerr 00000000 err 00000000 FCP CMPL: xb 00000821 Err 00012fcd
Configure NVMe/FC for a Marvell/QLogic adapter.
-
Verify that you are using the supported adapter driver and firmware versions:
cat /sys/class/fc_host/host*/symbolic_name
The following example shows driver and firmware versions:
QLE2772 FW:v9.10.11 DVR:v10.02.07.900-k-debug QLE2772 FW:v9.10.11 DVR:v10.02.07.900-k-debug
-
Verify that
ql2xnvmeenable
is set. This enables the Marvell adapter to function as an NVMe/FC initiator:cat /sys/module/qla2xxx/parameters/ql2xnvmeenable
The expected output is 1.
The NVMe/TCP protocol doesn't support the auto-connect operation. Instead, you can discover the NVMe/TCP subsystems and namespaces by performing the NVMe/TCP connect
or connect-all
operations manually.
-
Check that the initiator port can get the discovery log page data across the supported NVMe/TCP LIFs:
nvme discover -t tcp -w host-traddr -a traddr
Show example
nvme discover -t tcp -w 192.168.111.79 -a 192.168.111.14 Discovery Log Number of Records 8, Generation counter 10 =====Discovery Log Entry 0====== trtype: tcp adrfam: ipv4 subtype: unrecognized treq: not specified portid: 0 trsvcid: 8009 subnqn: nqn.1992-08.com.netapp:sn.154a5833c78c11ecb069d039ea359e4b:discovery traddr: 192.168.211.15 sectype: none =====Discovery Log Entry 1====== trtype: tcp adrfam: ipv4 subtype: unrecognized treq: not specified portid: 1 trsvcid: 8009 subnqn: nqn.1992-08.com.netapp:sn.154a5833c78c11ecb069d039ea359e4b:discovery traddr: 192.168.111.15 sectype: none =====Discovery Log Entry 2====== trtype: tcp adrfam: ipv4 subtype: unrecognized treq: not specified portid: 2 trsvcid: 8009 subnqn: nqn.1992-08.com.netapp:sn.154a5833c78c11ecb069d039ea359e4b:discovery traddr: 192.168.211.14 sectype: none
-
Verify that the other NVMe/TCP initiator-target LIF combinations can successfully retrieve discovery log page data:
nvme discover -t tcp -w host-traddr -a traddr
Show example
nvme discover -t tcp -w 192.168.111.79 -a 192.168.111.14 nvme discover -t tcp -w 192.168.111.79 -a 192.168.111.15 nvme discover -t tcp -w 192.168.211.79 -a 192.168.211.14 nvme discover -t tcp -w 192.168.211.79 -a 192.168.211.15
-
Run the
nvme connect-all
command across all the supported NVMe/TCP initiator-target LIFs across the nodes:nvme connect-all -t tcp -w host-traddr -a traddr -1 1800
Show example
nvme connect-all -t tcp -w 192.168.111.79 -a 192.168.111.14 -l 1800 nvme connect-all -t tcp -w 192.168.111.79 -a 192.168.111.15 -l 1800 nvme connect-all -t tcp -w 192.168.211.79 -a 192.168.211.14 -l 1800 nvme connect-all -t tcp -w 192.168.211.79 -a 192.168.211.15 -l 1800
Step 4: Optionally, enable 1MB I/O for NVMe/FC
ONTAP reports a Max Data Transfer Size (MDTS) of 8 in the Identify Controller data. This means the maximum I/O request size can be up to 1MB. To issue I/O requests of size 1MB for a Broadcom NVMe/FC host, you should increase the lpfc
value of the lpfc_sg_seg_cnt
parameter to 256 from the default value of 64.
|
These steps don't apply to Qlogic NVMe/FC hosts. |
-
Set the
lpfc_sg_seg_cnt
parameter to 256:cat /etc/modprobe.d/lpfc.conf
You should see an output similar to the following example:
options lpfc lpfc_sg_seg_cnt=256
-
Run the
dracut -f
command, and reboot the host. -
Verify that the value for
lpfc_sg_seg_cnt
is 256:cat /sys/module/lpfc/parameters/lpfc_sg_seg_cnt
Step 5: Validate NVMe-oF
Verify that the in-kernel NVMe multipath status, ANA status, and ONTAP namespaces are correct for the NVMe-oF configuration.
-
Verify that the in-kernel NVMe multipath is enabled:
cat /sys/module/nvme_core/parameters/multipath
You should see the following output:
Y
-
Verify that the appropriate NVMe-oF settings (such as, model set to NetApp ONTAP Controller and load balancing iopolicy set to round-robin) for the respective ONTAP namespaces correctly reflect on the host:
-
Display the subsystems:
cat /sys/class/nvme-subsystem/nvme-subsys*/model
You should see the following output:
NetApp ONTAP Controller NetApp ONTAP Controller
-
Display the policy:
cat /sys/class/nvme-subsystem/nvme-subsys*/iopolicy
You should see the following output:
round-robin round-robin
-
-
Verify that the namespaces are created and correctly discovered on the host:
nvme list
Show example
Node SN Model --------------------------------------------------------- /dev/nvme4n1 81Ix2BVuekWcAAAAAAAB NetApp ONTAP Controller Namespace Usage Format FW Rev ----------------------------------------------------------- 1 21.47 GB / 21.47 GB 4 KiB + 0 B FFFFFFFF
-
Verify that the controller state of each path is live and has the correct ANA status:
NVMe/FCnvme list-subsys /dev/nvme3n1
Show example
nvme-subsys3 - NQN=nqn.1992-08.com.netapp:sn.ab4fa6a5ba8b11ecbe3dd039ea359e4b:subsystem.rhel_161_Lpe32002 \ +- nvme0 fc traddr=nn-0x2048d039ea36a105:pn-0x204cd039ea36a105 host_traddr=nn-0x20000090fae0ec89:pn-0x10000090fae0ec89 live non-optimized +- nvme1 fc traddr=nn-0x2048d039ea36a105:pn-0x204ad039ea36a105 host_traddr=nn-0x20000090fae0ec89:pn-0x10000090fae0ec89 live optimized +- nvme2 fc traddr=nn-0x2048d039ea36a105:pn-0x204bd039ea36a105 host_traddr=nn-0x20000090fae0ec88:pn-0x10000090fae0ec88 live non-optimized +- nvme4 fc traddr=nn-0x2048d039ea36a105:pn-0x2049d039ea36a105 host_traddr=nn-0x20000090fae0ec88:pn-0x10000090fae0ec88 live optimized
NVMe/TCPnvme list-subsys /dev/nvme0n1
Show example
nvme-subsys0 - NQN=nqn.1992-08.com.netapp:sn.154a5833c78c11ecb069d039ea359e4b:subsystem.rhel_tcp_165 \ +- nvme0 tcp traddr=192.168.111.15 trsvcid=4420 host_traddr=192.168.111.79 live non-optimized +- nvme1 tcp traddr=192.168.111.14 trsvcid=4420 host_traddr=192.168.111.79 live optimized +- nvme2 tcp traddr=192.168.211.15 trsvcid=4420 host_traddr=192.168.211.79 live non-optimized
-
Verify that the NetApp plug-in displays the correct values for each ONTAP namespace device:
Columnnvme netapp ontapdevices -o column
Show example
Device Vserver Namespace Path ----------------------- ------------------------------ /dev/nvme0n1 vs_tcp /vol/vol1/ns1 NSID UUID Size ------------------------------------------------------------ 1 338d73ce-b5a8-4847-9cc9-b127c75d8855 21.47GB
JSONnvme netapp ontapdevices -o json
Show example
{ "ONTAPdevices" : [ { "Device" : "/dev/nvme0n1", "Vserver" : "vs_tcp79", "Namespace_Path" : "/vol/vol1/ns1", "NSID" : 1, "UUID" : "338d73ce-b5a8-4847-9cc9-b127c75d8855", "Size" : "21.47GB", "LBA_Data_Size" : 4096, "Namespace_Size" : 5242880 }, ] }
Step 6: Review the known issues
These are the known issues:
NetApp Bug ID | Title | Description |
---|---|---|
RHEL 8.8 NVMe-oF hosts create duplicate persistent discovery controllers (PDCs) |
On NVMe-oF hosts, you can use the "nvme discover -p" command to create PDCs. When this command is used, only one PDC should be created per initiator-target combination. However, if you are running RHEL 8.8 on an NVMe-oF host, a duplicate PDC is created each time "nvme discover -p" is executed. This leads to unnecessary usage of resources on both the host and the target. |