Install the Ethernet Switch Health Monitor configuration file
Follow this procedure to install the applicable configuration file for Ethernet switch health monitoring of NVIDIA cluster switches. Supported models are:
-
MSN2100-CB2FC
-
MSN2100-CB2RC
-
X190006-PE
-
X190006-PI
|
This installation procedure applies to ONTAP 9.10.1 and later. |
-
Verify that you need to download the configuration file by running
system switch ethernet show
and checking if OTHER is shown for your model.If your model is still showing OTHER after applying the configuration file, contact NetApp support.
-
Make sure that the ONTAP cluster is up and running.
-
Enable SSH to use all of the features available in CSHM.
-
Clear the
/mroot/etc/cshm_nod/nod_sign/
directory on all nodes:-
Enter the nodeshell:
system node run -node <name>
-
Change to advanced privilege:
priv set advanced
-
List the configuration files in the
/etc/cshm_nod/nod_sign
directory. If the directory exists and contains configuration files, it lists the file names.ls /etc/cshm_nod/nod_sign
-
Delete all NOD files corresponding to your connected switch models.
If you are unsure, remove all NOD files for the supported models listed above, then download and install the latest NOD files for those same models.
rm /etc/cshm_nod/nod_sign/<filename>
-
Confirm that the deleted NOD files are no longer in the directory:
ls /etc/cshm_nod/nod_sign
-
-
Download the Ethernet switch health monitor configuration zip file based on the corresponding ONTAP release version. This file is available from the NVIDIA Ethernet switches page.
-
On the NVIDIA SN2100 Software download page, select Nvidia CSHM File.
-
On the Caution/Must read page, select the check box to agree.
-
On the End User License Agreement page, select the check box to agree and click Accept & Continue.
-
On the Nvidia CSHM File - Download page, select the applicable configuration file. The following files are available:
-
-
MSN2100-CB2FC-v1.4.zip
-
MSN2100-CB2RC-v1.4.zip
-
X190006-PE-v1.4.zip
-
X190006-PI-v1.4.zip
-
MSN2100-CB2FC_PRIOR_R9.15.1-v1.4.zip
-
MSN2100-CB2RC_PRIOR_R9.15.1-v1.4.zip
-
X190006-PE_PRIOR_9.15.1-v1.4.zip
-
X190006-PI_PRIOR_9.15.1-v1.4.zip
-
Access the advanced mode setting from one of the ONTAP systems in the cluster.
set -privilege advanced
-
Run the switch health monitor configure command.
cluster1::> system cluster-switch configure-health-monitor -node * -package-url http://192.168.2.20/usr/download/[filename.zip]
-
Verify that the command output ends with the following text for your ONTAP version:
Ethernet switch health monitoring installed the configuration file.
SHM installed the configuration file.
CSHM downloaded package processed successfully.
If an error occurs, contact NetApp support.
-
Wait up to twice the Ethernet switch health monitor polling interval, found by running
system switch ethernet polling-interval show
, before completing the next step. -
Run the command
system switch ethernet show
on the ONTAP system and make sure that the cluster switches are discovered with the monitored field set to True and the serial number field not showing Unknown.cluster1::> system switch ethernet show